ADM1034ARQZ-R7 ON Semiconductor, ADM1034ARQZ-R7 Datasheet - Page 34

no-image

ADM1034ARQZ-R7

Manufacturer Part Number
ADM1034ARQZ-R7
Description
IC THERM/FAN SPEED CTLR 16-QSOP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADM1034ARQZ-R7

Function
Fan Control, Temp Monitor
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 50. Register 0x12, Remote 2 Low Limit, Power−On Default 0x54, Lock = N, S/W Reset = N
Table 51. Register 0x13, Remote 2 THERM Limit, Power−On Default 0x95, Lock = Y, S/W Reset = N
Table 52. Register 0x16, Local Offset Register, Power−On Default 0x00, Lock = Y, S/W Reset = N
Table 53. Register 0x17, Remote 1 Offset Register, Power−On Default 0x00, Lock = Y, S/W Reset = N
Table 54. Register 0x18, Remote 2 Offset Register, Power−On Default 0x00, Lock = Y, S/W Reset = N
Table 55. Register 0x19, THERM Timer % Limit, Power−On Default 0xFF, Lock = Y, S/W Reset = N
Table 56. Register 0x1A, THERM Hysteresis, Power−On Default 0x05, Lock = Y, S/W Reset = N
<7:0>
<7:0>
<7:0>
<7:0>
<7:0>
<7:0>
<7:4>
<3:0>
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Remote 2 Low Limit
Remote 2 THERM
Limit
Local Offset
Remote 1 Offset
Remote 2 Offset
THERM Timer on%
Limit
Reserved
THERM Hysteresis
Name
Name
Name
Name
Name
Name
Name
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
When the Remote 2 temperature falls below this temperature, the corresponding
interrupt status bit is set.
When the Remote 2 temperature exceeds this temperature, the corresponding status bit
is set and the THERM output is activated.
Allows a twos compliment offset to be automatically added to or subtracted from the
local temperature measurement. Resolution = 0.125°C. Maximum offset from -16°C to
+15.875°C. Default = 0.
Allows a twos compliment offset to be automatically added to or subtracted from the
Remote 1 temperature measurement. Resolution = 0.125°C.
Maximum offset from -16°C to +15.875°C. Default = 0.
Allows a twos compliment offset to be automatically added to or subtracted from the
Remote 2 temperature measurement. Resolution = 0.125°C.
Maximum offset from -16°C to +15.875°C. Default = 0.
If the THERM is asserted for greater than this limit on the time window, the
corresponding status bit is set.
Reserved.
An unsigned THERM hysteresis value, LSB = 1°C. Once THERM has been activated
on a temperature channel, the THERM limit – hysteresis is deactivated if the
temperature drops below THERM.
http://onsemi.com
34
Description
Description
Description
Description
Description
Description
Description

Related parts for ADM1034ARQZ-R7