ADM1026JSTZ-REEL ON Semiconductor, ADM1026JSTZ-REEL Datasheet - Page 7

IC CNTRL SYS REF/EEPROM 48-LQFP

ADM1026JSTZ-REEL

Manufacturer Part Number
ADM1026JSTZ-REEL
Description
IC CNTRL SYS REF/EEPROM 48-LQFP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADM1026JSTZ-REEL

Function
Hardware Monitor
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 100°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
0°C ~ 100°C
Mounting Type
Surface Mount
Package / Case
48-LFQFP
Full Temp Accuracy
+/- 3 C
Digital Output - Bus Interface
Serial (2-Wire)
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM1026JSTZ-REEL
Manufacturer:
AD
Quantity:
6 906
Part Number:
ADM1026JSTZ-REEL
Manufacturer:
ON Semiconductor
Quantity:
10 000
Part Number:
ADM1026JSTZ-REEL
Manufacturer:
ON
Quantity:
2 977
Part Number:
ADM1026JSTZ-REEL
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
ADM1026JSTZ-REEL7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
1. All voltages are measured with respect to GND, unless otherwise specified.
2. Typicals are at T
3. Timing specifications are tested at logic levels of V
4. Total unadjusted error (TUE) includes offset, gain, and linearity errors of the ADC, multiplexer, and on−chip input attenuators. V
5. Total analog monitoring cycle time is nominally 273 ms, made up of 18 ms × 11.38 ms measurements on analog input and internal temperature
6. The total fan count is based on two pulses per revolution of the fan tachometer output. The total fan monitoring time depends on the number
7. ADD is a three−state input that may be pulled high, low, or left open circuit.
8. Logic inputs accept input high voltages up to 5.0 V even when device is operating at supply voltages below 5.0 V.
9. Endurance is qualified to 100,000 cycles as per JEDEC Std. 22 method A117, and measured at −40°C, +25°C, and +85°C. Typical endurance
10. Retention lifetime equivalent at junction temperature (T
ELECTRICAL CHARACTERISTICS
SERIAL BUS TIMING
Start Hold Time, t
SCL Low Time, t
SCL High Time, t
SCL, SDA Rise Time, t
SCL, SDA Fall Time, t
Data Setup Time, t
Data Hold Time, t
only for V
channels, and 2 ms × 34.13 ms measurements on external temperature channels.
of fans connected and the fan speed. See the Fan Speed Measurement section for more details.
at +25°C is 700,000 cycles.
energy of 0.6 V derates with junction temperature as shown in Figure 15.
SDA
SCL
BAT
P
voltages greater than 1.5 V (see Figure 14).
t
LOW
BUF
HIGH
HD; STA
HD; DAT
A
SU; DAT
Parameter
= 25°C and represent the most likely parametric norm. Shutdown current typ is measured with V
S
f
r
t
t
HD; STA
LOW
t
HD; DAT
t
R
T
A
= T
Figure 2. Serial Bus Timing Diagram
MIN
to T
IL
t
HIGH
= 0.8 V for a falling edge and V
J
MAX
) = 55°C as per JEDEC Std. 22 method A117. Retention lifetime based on activation
http://onsemi.com
t
Test Conditions/Comments
F
, V
CC
= V
7
t
SU; DAT
MIN
to V
MAX
S
, unless otherwise noted. (Note 1, 2, and 3)
t
IH
SU; STA
= 2.1 V for a rising edge.
t
HD; STA
Min
250
300
4.0
4.7
4.0
Typ
t
SU; STO
CC
1000
Max
300
= 3.3V.
BAT
P
is accurate
Unit
ms
ms
ms
ns
ns
ns
ns

Related parts for ADM1026JSTZ-REEL