LUCL9310AP-D AGERE [Agere Systems], LUCL9310AP-D Datasheet - Page 58

no-image

LUCL9310AP-D

Manufacturer Part Number
LUCL9310AP-D
Description
Line Interface and Line Access Circuit Full-Feature SLIC,Ringing Relay,and Test Access Device
Manufacturer
AGERE [Agere Systems]
Datasheet
Full-Feature SLIC, Ringing Relay, and Test Access Device
ac Applications
Third-Generation Codec ac Interface Network: Complex Termination
Table 24. L9310 Parts List for Agere T8536 Third-Generation Codec Meter Pulse Application, Dual Battery
* See your Agere Account Representative for a recommended secondary protection device.
58
Fault Protection
R
R
Protector*
Protector*
Power Supply
Diode
C
C
C
C
C
Supervision
C
R
R
PPM
C
R
ac Interface
R
R
C
C
PR
PT
VBAT1
VBAT2
CC
DD
F2
RTF
RTF
RS1
PPM
PPM
GX
CIN
TX
C1
Name
Operation, ac and dc Parameters, Fully Programmable
(continued)
180 V to 320 V
100 V to 130 V
0.015 F
1N4004
17.4 k
6.34 k
0.01 F
0.15 F
0.33 F
20 M
0.1 F
0.1 F
0.1 F
0.1 F
0.1 F
400
Value
1 M
50
50
Tolerance
20%
20%
20%
20%
20%
20%
20%
20%
20%
1%
1%
1%
5%
1%
1%
5%
Fusible or
Fusible or
Rating
1/16 W
1/16 W
1/16 W
1/16 W
100 V
100 V
100 V
PTC
PTC
50 V
10 V
10 V
10 V
10 V
2 W
5 V
Protection resistor.
Protection resistor.
Ring-side secondary protector.
Tip-side secondary protector.
Reverse battery current.
Filter capacitor.
Filter capacitor.
Filter capacitor.
Filter capacitor.
Filter capacitor.
Ring trip filter capacitor.
Ring trip filter resistor.
Sets ring trip threshold.
ac couple PPM input.
PPM hybrid rejection.
Sets T/R to VITR transconductance.
dc bias.
ac/dc separation.
dc blocking capacitor.
(continued)
Function
Agere Systems Inc.
July 2001

Related parts for LUCL9310AP-D