Operating States
Input State Coding
Table 2. Primary Control States
Table 3. Secondary Control States
Table 4. Supervision Coding
0 = off-hook or ring trip
1 = on-hook and no ring trip
B3
1
1
1
1
1
1
1
1
B3
X
0
0
0
0
0
0
0
0
B2
Pin NSTAT
0
0
0
0
1
1
1
1
B2
X
0
0
0
0
1
1
1
1
B1
0
0
1
1
0
0
1
1
(continued)
(continued)
B0
0
1
0
1
0
1
0
1
B1
X
0
0
1
1
0
0
1
1
Type
PPM
PPM
0 = ring ground
1 = no ring ground
Test
Test
Test
Test
Test
Test
B0
X
0
1
0
1
0
1
0
1
Full-Feature SLIC, Ringing Relay, and Test Access Device
TESTLEV, TESTSIG Tip/ring voltage
TESTLEV, TESTSIG Tip voltage
TESTLEV, TESTSIG Ring voltage
TESTLEV, TESTSIG VTX—current
TESTLEV
TESTLEV, TESTSIG VITR—current
PPMIN, PPMOUT
PPM Off
Pin TRGDET
RESET
Active
1
1
1
1
1
1
1
1
0
Scan
Powerup, forward battery
Powerup, reverse battery
Tip and ring amp
Ring
Tip amp
Ring amp
Disconnect, break before make
Disconnect, break before make
V
PPM On
PPM Off/TEST Off
REF
State
State
15