LUCL9310AP-D AGERE [Agere Systems], LUCL9310AP-D Datasheet - Page 55

no-image

LUCL9310AP-D

Manufacturer Part Number
LUCL9310AP-D
Description
Line Interface and Line Access Circuit Full-Feature SLIC,Ringing Relay,and Test Access Device
Manufacturer
AGERE [Agere Systems]
Datasheet
July 2001
Agere Systems Inc.
ac Applications
First-Generation Codec ac Interface Network: Complex Termination
Basic Loop Start Application Using T7504 Type Codec (continued)
Table 23. L9310 Parts List for Agere T7504 First-Generation Codec Complex Termination, Meter Pulse
* See your Agere Account Representative for a recommended Secondary Protection Device.
Fault Protection
R
R
Protector*
Protector*
Power Supply
Diode
C
C
C
C
C
dc Profile
R
R
R
Supervision
C
R
R
R
PPM
C
R
VPROG
VREF
PR
PT
VBAT1
VBAT2
CC
DD
F2
OVH
RTF
RTF
RS1
LCTH
PPM
PPM
Name
Application, Dual Battery Operation
180 V to 320 V
100 V to 130 V
(continued)
1N4004
23.2 k
16.9 k
69.8 k
17.4 k
0.01 F
0.01 F
0.1 F
0.1 F
0.1 F
0.1 F
0.1 F
400
Value
59 k
1 M
50
50
Tolerance
20%
20%
20%
20%
20%
20%
20%
Full-Feature SLIC, Ringing Relay, and Test Access Device
1%
1%
1%
1%
1%
1%
5%
1%
1%
Fusible
or PTC
Fusible
or PTC
1/16 W
1/16 W
1/16 W
1/16 W
1/16 W
1/16 W
Rating
100 V
100 V
100 V
50 V
10 V
10 V
2 W
5 V
Protection resistor.
Protection resistor.
Ring-side secondary protector.
Tip-side secondary protector.
Reverse battery current.
Filter capacitor.
Filter capacitor.
Filter capacitor.
Filter capacitor.
Filter capacitor.
With R
With R
With R
Ring trip filter capacitor.
Ring trip filter resistor.
Sets ring trip threshold.
With R
ac-couple PPM input.
PPM hybrid rejection.
VREF
VREF
VPROG
VREF
, fix loop supervision threshold.
fix overhead voltage.
fix dc current limit.
fix dc current limit.
Function
(continued)
55