Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features
Datasheet
SMSC EMC6D103
6.3.1
6.3.2
SAMPLING ORDER
Continuous Monitoring Mode
In the continuous monitoring mode, the sampling and conversion process is performed continuously
for each voltage and temperature reading after the Start bit is set high. The time for each voltage and
temperature reading is shown above for each measurement option.
The continuous monitoring function is started by doing a write to the Ready/Lock/Start Register, setting
the Start bit (Bit 0) high. The part then performs a “round robin” sampling of the inputs, in the order
shown below (see
Table 6.2, “Conversion Cycle Timing,” on page
When the continuous monitoring function is started, it cycles through each measurement in sequence,
and it continuously loops through the sequence approximately once every 223 ms (default - see
Table 6.2, “Conversion Cycle Timing,” on page
in the Limit registers. When the measured value violates the programmed limit the Hardware Monitor
Block will set a corresponding status bit in the Interrupt Status Registers.
If auto fan option is selected, the hardware will adjust the operation of the fans accordingly. See
Fan Control Operating Mode on page
The results of the sampling and conversions can be found in the Reading Registers and are available
at any time.
Cycle Monitoring Mode
In cycle monitoring mode, the part completes all sampling and conversions, then waits approximately
one second to repeat the process. It repeats the sampling and conversion process typically every 1.2
seconds (1.4 sec max - default averaging enabled). The sampling and conversion of each voltage and
temperature reading is performed once every monitoring cycle. This is a power saving mode.
The cycle monitoring function is started by doing a write to the Ready/Lock/Start Register, setting the
Start bit (Bit 0) high. The part then performs a “round robin” sampling of the inputs, in the order shown
above.
When the cycle monitoring function is started, it cycles through each measurement in sequence, and
it produces a converted voltage and temperature reading for each input. The state machine waits
approximately one second before repeating this process. Each measured value is compared to values
stored in the Limit registers. When the measured value violates (or is equal to) the programmed limit
the Hardware Monitor Block will set a corresponding status bit in the Interrupt Status Registers.
If auto fan option is selected, the hardware will adjust the operation of the fans accordingly. See the
section titled
1
2
3
4
5
6
7
8
Auto Fan Control Operating Mode on page
Table
Table 6.3 ADC Conversion Sequence
6.3). Sampling of all values occurs in a nominal 223 ms (default - see
DATASHEET
35.
25
24). Each measured value is compared to values stored
24).
Remote Diode Temp Reading 1
Remote Diode Temp Reading 2
Ambient Temperature reading
Vccp (processor) reading
35.
+2.5V reading
+12V reading
VCC reading
+5V reading
REGISTER
Revision 0.4 (04-04-05)