AK4646EN AKM [Asahi Kasei Microsystems], AK4646EN Datasheet - Page 39

no-image

AK4646EN

Manufacturer Part Number
AK4646EN
Description
Stereo CODEC with MIC/SPK-AMP
Manufacturer
AKM [Asahi Kasei Microsystems]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AK4646EN-L
Manufacturer:
AKM
Quantity:
20 000
2. ALC Recovery Operation
The ALC recovery operation waits for the WTM2-0 bits (Table 26) to be set after completing the ALC limiter operation.
If the input signal does not exceed “ALC recovery waiting counter reset level” (Table 23) during the wait time, the ALC
recovery operation is done. The VOL value is automatically incremented by RGAIN1-0 bits (Table 27) up to the set
reference level (Table 28) with zero crossing detection which timeout period is set by ZTM1-0 bits (Table 25). Then the
IVL and IVR are set to the same value for both channels. The ALC recovery operation is done at a period set by WTM2-0
bits. When zero cross is detected at both channels during the wait period set by WTM2-0 bits, the ALC recovery operation
waits until WTM2-0 period and the next recovery operation is done.
For example, when the current VOL value is 30H and RGAIN1-0 bits are set to “01”, VOL is changed to 32H by the auto
limiter operation and then the input signal level is gained by 0.75dB (=0.375dB x 2). When the VOL value exceeds the
reference level (REF7-0), the VOL values are not increased.
When
during the ALC recovery operation, the waiting timer of ALC recovery operation is reset. When
the waiting timer of ALC recovery operation starts.
The ALC operation corresponds to the impulse noise. When the impulse noise is input, the ALC recovery operation
becomes faster than a normal recovery operation. When large noise is input to microphone instantaneously, the quality of
small level in the large noise can be improved by this fast recovery operation. The speed of first recovery operation is set
by RFST1-0 bits(Table 30).
MS0557-E-02
“ALC recovery waiting counter reset level (LMTH1-0) ≤ Output Signal < ALC limiter detection level (LMTH1-0)”
“ALC recovery waiting counter reset level (LMTH1-0) > Output Signal”,
WTM2
0
0
0
0
1
1
1
1
WTM1
0
0
1
1
0
0
1
1
RGAIN1
WTM0
0
0
1
1
Table 26. ALC Recovery Operation Waiting Period
0
1
0
1
0
1
0
1
Table 27. ALC Recovery GAIN Step
RGAIN0
16384/fs
1024/fs
2048/fs
4096/fs
8192/fs
128/fs
256/fs
512/fs
0
1
0
1
- 39 -
1 step
2 step
3 step
4 step
ALC Recovery Operation Waiting Period
1024ms
2048ms
128ms
256ms
512ms
8kHz
16ms
32ms
64ms
GAIN STEP
0.375dB
0.750dB
1.125dB
1.500dB
1024ms
16kHz
128ms
256ms
512ms
16ms
32ms
64ms
8ms
(default)
44.1kHz
185.8ms
371.5ms
11.6ms
23.2ms
46.4ms
92.9ms
2.9ms
5.8ms
(default)
[AK4646]
2007/05

Related parts for AK4646EN