Z8S180 Zilog., Z8S180 Datasheet - Page 78

no-image

Z8S180

Manufacturer Part Number
Z8S180
Description
ENHANCED Z180 MICROPROCESSOR
Manufacturer
Zilog.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8S18010FEC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FEC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FEG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FSC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FSC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
Z8S18010FSCZ180
Manufacturer:
ZILOG
Quantity:
748
Part Number:
Z8S18010FSG
Manufacturer:
Zilog
Quantity:
426
Part Number:
Z8S18010PSG
Manufacturer:
Zilog
Quantity:
48
Part Number:
Z8S18010VEC
Manufacturer:
ZILOG
Quantity:
12 388
Part Number:
Z8S18010VSC
Manufacturer:
ZILOG
Quantity:
250
Z 8018x Fam il y
M PU Us e r M anual
63
MMU and RESET
During RESET, all bits of the CA field of CBAR are set to
while all bits
1
of the BA field of CBAR, CBR and BBR are reset to
. The logical 64KB
0
address space corresponds directly with the first 64KB
to
)
0000H
FFFFH
of the 1024KB
. to
) physical address space. Thus, after
00000H
FFFFFH
RESET, the Z8X180 begins execution at logical and physical address 0.
MMU Register Access Timing
When data is written into CBAR, CBR or BBR, the value is effective
from the cycle immediately following the I/O write cycle which updates
these registers.
During MMU programming insure that CPU program execution is not
disrupted. The next cycle following MMU register programming is
normally an Op Code fetch from the newly translated address. One
technique is to localize all MMU programming routines in a Common
Area that is always enabled.
UM005001-ZMP0400