SCAN18245TSSCX Fairchild Semiconductor, SCAN18245TSSCX Datasheet - Page 3

no-image

SCAN18245TSSCX

Manufacturer Part Number
SCAN18245TSSCX
Description
IC TRANSCVR 3ST NON-INV 56SSOP
Manufacturer
Fairchild Semiconductor
Series
SCANr
Datasheet

Specifications of SCAN18245TSSCX

Logic Type
Transceiver, Non-Inverting
Number Of Elements
2
Number Of Bits Per Element
9
Current - Output High, Low
32mA, 64mA
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
56-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SCAN18245TSSCX
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Description of Boundary-Scan Circuitry
The scan cells used in the BOUNDARY-SCAN register are
one of the following two types depending upon their loca-
tion. Scan cell TYPE1 is intended to solely observe system
data, while TYPE2 has the additional ability to control sys-
tem data. (See IEEE Standard 1149.1 Figure 10–11 for a
further description of scan cell TYPE1 and Figure 10–12 for
a further description of scan cell TYPE2.)
Scan cell TYPE1 is located on each system input pin while
scan cell TYPE2 is located at each system output pin as
well as at each of the two internal active-high output enable
signals. AOE controls the activity of the A-outputs while
BOE controls the activity of the B-outputs. Each will acti-
vate their respective outputs by loading a logic high.
The BYPASS register is a single bit shift register stage
identical to scan cell TYPE1. It captures a fixed logic low.
The INSTRUCTION register is an eight-bit register which
captures the value 00111101.
Bypass Register Scan Chain Definition
Logic 0
Scan Cell TYPE1
Scan Cell TYPE2
3
The two least significant bits of this captured value (01) are
required by IEEE Std 1149.1. The upper six bits are unique
to the SCAN18245T device. SCAN CMOS Test Access
Logic devices do not include the IEEE 1149.1 optional
identification register. Therefore, this unique captured
value can be used as a “pseudo ID” code to confirm that
the correct device is placed in the appropriate location in
the boundary scan chain.
00000000
10000001
10000010
00000011
All Others
Instruction Register Scan Chain Definition
Instruction Code
MSB
LSB
SAMPLE/PRELOAD
www.fairchildsemi.com
Instruction
EXTEST
BYPASS
CLAMP
HIGHZ

Related parts for SCAN18245TSSCX