HY27UF081G2M Hynix Semiconductor, HY27UF081G2M Datasheet - Page 16

no-image

HY27UF081G2M

Manufacturer Part Number
HY27UF081G2M
Description
(HY27UF(08/16)1G2M / HY27SF(08/16)1G2M) 1Gbit (128Mx8bit/64Mx16bit) NAND Flash Memory
Manufacturer
Hynix Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HY27UF081G2M
Manufacturer:
HY
Quantity:
1 000
Part Number:
HY27UF081G2M
Manufacturer:
HY
Quantity:
1 000
Part Number:
HY27UF081G2M
Manufacturer:
HY
Quantity:
5 530
Part Number:
HY27UF081G2M-TCB
Manufacturer:
HYNIX
Quantity:
16
Part Number:
HY27UF081G2M-TPCB
Manufacturer:
HYNIX/海力士
Quantity:
20 000
Company:
Part Number:
HY27UF081G2M-TPCB
Quantity:
848
Preliminary
HY27UF(08/16)1G2M Series
HY27SF(08/16)1G2M Series
1Gbit (128Mx8bit / 64Mx16bit) NAND Flash
4. OTHER FEATURES
4.1 Data Protection.
The device is designed to offer protection from any involuntary program/erase during power-transitions. An internal
voltage detector disables all functions whenever Vcc is below about 1.5V. WP# pin provides hardware protection and is
recommended to be kept at VIL during power-up and power-down. A recovery time of minimum 10us is required
before internal circuit gets ready for any command sequences as shown in Figure 26. The two-step command
sequence for program/erase provides additional software protection.
4.2 Ready/Busy.
The device has a Ready/Busy output that provides method of indicating the completion of a page program, erase,
copy-back, cache program and random read completion. The RB# pin is normally high and goes to low when the
device is busy (after a reset, read, program, erase operation). It returns to high when the internal controller has fin-
ished the operation. The pin is an open-drain driver thereby allowing two or more RB# outputs to be Or-tied. Because
pull-up resistor value is related to tr(RB#) and current drain during busy (Ibusy), an appropriate value can be obtained
with the following reference chart (Fig.27). Its value can be determined by the following guidance.
4.3 Power-On Auto-Read
The device is designed to offer automatic reading of the first page without command and address input sequence dur-
ing power-on.
An internal voltage detector enables auto-page read functions when Vcc reaches about 1.8V. PRE pin controls activa-
tion of auto- page read function. Auto-page read function is enabled only when PRE pin is logic high state. Serial
access may be done after power-on without latency. Power-On Auto Read mode is available only on 3.3V device
(HY27UF(08/16)1G2M).
Rev 0.6 / Mar. 2005
16

Related parts for HY27UF081G2M