nRF24LE1 Nordic VLSI, nRF24LE1 Datasheet - Page 86

no-image

nRF24LE1

Manufacturer Part Number
nRF24LE1
Description
Manufacturer
Nordic VLSI
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
nRF24LE1-017Q24-R
Quantity:
1 411
Part Number:
nRF24LE1-017Q24-R7
Manufacturer:
NORDIC
Quantity:
20 000
Part Number:
nRF24LE1-017Q32-R
Manufacturer:
NORDIC
Quantity:
1 534
Part Number:
nRF24LE1-017Q32-R7
Manufacturer:
NORDIC
Quantity:
20 000
Part Number:
nRF24LE1-DNQ24-R
Manufacturer:
NORDIC
Quantity:
3 500
Part Number:
nRF24LE1-F16Q32-R
Manufacturer:
VISHAY
Quantity:
50 000
Part Number:
nRF24LE1-F16Q32-R
0
Company:
Part Number:
nRF24LE1-F16Q32-R/E
Quantity:
20 000
Company:
Part Number:
nRF24LE1-F16Q32-T
Quantity:
100
Part Number:
nRF24LE1-F16Q48
Manufacturer:
OKI
Quantity:
2 850
Part Number:
nRF24LE1-F16Q48-R
Manufacturer:
NORDIC
Quantity:
20 000
Part Number:
nRF24LE1-O17Q24-R
Manufacturer:
NORDIC
Quantity:
34 661
Part Number:
nRF24LE1-O17Q24-R7
Manufacturer:
NORDIC
Quantity:
20 000
Part Number:
nRF24LE1-O17Q24-T
Manufacturer:
NORDIC
Quantity:
20 000
Company:
Part Number:
nRF24LE1-O17Q32
Quantity:
1 800
Part Number:
nRF24LE1-O17Q48
Manufacturer:
GENERAL
Quantity:
795
Part Number:
nRF24LE1D
Manufacturer:
INFINEON
Quantity:
67 000
nRF24LE1 Preliminary Product Specification
8.3
8.3.1
In timer mode, Timer 0/1 is incremented every 12 clock cycles.
In the counter mode, the Timer 0/1 is incremented when the falling edge is detected at the corresponding
input pin T0 for Timer 0, or T1 for Timer 1.
Since it takes two clock cycles to recognize a 1-to-0 event, the maximum input count rate is ½ of the oscil-
lator frequency. There are no restrictions on the duty cycle, however to ensure proper recognition of 0 or 1
state, an input should be stable for at least 1 clock cycle.
Timer 0 and Timer 1 status and control are in TCON and TMOD register. The actual 16-bit Timer 0 value is in
TH0 (8 msb) and TL0 (8 lsb), while Timer 1 uses TH1 and TL1.
Four operating modes can be selected for Timer 0/1. Two Special Function Registers, TMOD and TCON,
are used to select the appropriate mode.
8.3.1.1
In mode 0, Timer 0/1 is configured as a 13-bit register (TL0/TL1 = 5 bits, TH0/TH1 = 8 bits). The upper
three bits of TL0/TL1 are unchanged and should be ignored.
In mode 1 Timer 0/1 is configured as a 16-bit register.
Revision 1.1
Note: Timer input pins T0, T1 and, T2 must be configured as described in
Functional description
Timer 0 and Timer 1
INTi
GATE
Mode 0 and Mode 1
Fosc
TRi
Ti
/12
Figure 39. Timer 0 and Timer 1 in mode 0 and 1
C/T=0
C/T=1
86 of 191
TLi
THi
section 8.4 on page
TFi
89.

Related parts for nRF24LE1