ST7260E1 STMicroelectronics, ST7260E1 Datasheet - Page 58

no-image

ST7260E1

Manufacturer Part Number
ST7260E1
Description
LOW SPEED USB 8-BIT MCU FAMILY WITH UP TO 8K FLASH/ROM AND SERIAL COMMUNICATION INTERFACE (SCI)
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST7260E1

4 Or 8 Kbytes Program Memory
high density Flash (HDFlash), or FastROM with readout and write protection
Watchdog timer (WDG)
58/139
One pulse mode
One Pulse mode enables the generation of a pulse when an external event occurs. This
mode is selected via the OPM bit in the CR2 register.
The one pulse mode uses the Input Capture1 function and the Output Compare1 function.
Procedure
To use One Pulse mode:
1.
2.
3.
Figure 34. One pulse mode cycle
Then, on a valid event on the ICAP1 pin, the counter is initialized to FFFCh and OLVL2 bit is
loaded on the OCMP1 pin, the ICF1 bit is set and the value FFFDh is loaded in the IC1R
register.
Because the ICF1 bit is set when an active edge occurs, an interrupt can be generated if the
ICIE bit is set.
Clearing the Input Capture interrupt request (that is, clearing the ICFi bit) is done in two
steps:
1.
2.
Load the OC1R register with the value corresponding to the length of the pulse (see the
formula below).
Select the following in the CR1 register:
Select the following in the CR2 register:
Reading the SR register while the ICFi bit is set.
An access (read or write) to the ICiLR register.
Using the OLVL1 bit, select the level to be applied to the OCMP1 pin after the
pulse.
Using the OLVL2 bit, select the level to be applied to the OCMP1 pin during the
pulse.
Select the edge of the active transition on the ICAP1 pin with the IEDG1 bit (the
ICAP1 pin must be configured as floating input).
Set the OC1E bit, the OCMP1 pin is then dedicated to the Output Compare 1
function.
Set the OPM bit.
Select the timer clock CC[1:0] (see
event occurs
on ICAP1
counter =
When
When
OC1R
Table
OCMP1 = OLVL2
Counter is reset
OCMP1 = OLVL1
ICR1 = Counter
ICF1 bit is set
to FFFCh
32).
ST7260xx

Related parts for ST7260E1