AT90USB162 Atmel Corporation, AT90USB162 Datasheet - Page 254

no-image

AT90USB162

Manufacturer Part Number
AT90USB162
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT90USB162

Flash (kbytes)
16 Kbytes
Pin Count
32
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
22
Ext Interrupts
21
Usb Transceiver
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Uart
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
0.5
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
5
Input Capture Channels
1
Pwm Channels
4
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90USB162-16AU
Manufacturer:
Atmel
Quantity:
30 024
Part Number:
AT90USB162-16AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT90USB162-16AU
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
AT90USB162-16AUR
Manufacturer:
Atmel
Quantity:
2 751
Part Number:
AT90USB162-16AUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT90USB162-16MU
Manufacturer:
Atmel
Quantity:
42 926
Part Number:
AT90USB162-16MU
Manufacturer:
ATMEL
Quantity:
3 470
Part Number:
AT90USB162-16MU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT90USB162-16MUR
Manufacturer:
TT
Quantity:
400 000
25.6.11
25.6.12
254
AT90USB82/162
Programming the Lock Bits
Reading the Fuse and Lock Bits
Figure 25-5. Programming the FUSES Waveforms
The algorithm for programming the Lock bits is as follows (refer to
page 249
The Lock bits can only be cleared by executing Chip Erase.
The algorithm for reading the Fuse and Lock bits is as follows (refer to
on page 249
1. A: Load Command “0010 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs the Lock bit. If LB mode 3 is programmed
3. Give WR a negative pulse and wait for RDY/BSY to go high.
1. A: Load Command “0000 0100”.
2. Set OE to “0”, and BS2, BS1 to “00”. The status of the Fuse Low bits can now be read
3. Set OE to “0”, and BS2, BS1 to “11”. The status of the Fuse High bits can now be read
4. Set OE to “0”, and BS2, BS1 to “10”. The status of the Extended Fuse bits can now be
5. Set OE to “0”, and BS2, BS1 to “01”. The status of the Lock bits can now be read at
6. Set OE to “1”.
RESET +12V
(LB1 and LB2 is programmed), it is not possible to program the Boot Lock bits by any
External Programming mode.
at DATA (“0” means programmed).
at DATA (“0” means programmed).
read at DATA (“0” means programmed).
DATA (“0” means programmed).
RDY/BSY
PAGEL
XTAL1
DATA
for details on Command and Data loading):
XA1
XA0
BS1
BS2
WR
OE
for details on Command loading):
0x40
A
DATA
C
Write Fuse Low byte
XX
0x40
A
DATA
C
Write Fuse high byte
XX
“Programming the Flash” on
0x40
A
“Programming the Flash”
DATA
C
Write Extended Fuse byte
XX
7707F–AVR–11/10