PEB 3086 F V1.4 Infineon Technologies, PEB 3086 F V1.4 Datasheet - Page 171

no-image

PEB 3086 F V1.4

Manufacturer Part Number
PEB 3086 F V1.4
Description
IC ISDN ACCESS CTRLR TQFP64
Manufacturer
Infineon Technologies
Series
ISAC™r
Datasheet

Specifications of PEB 3086 F V1.4

Function
Subscriber Access Controller
Interface
HDLC, IOM-2, ISDN, Parallel, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-LFQFP
Includes
D-Channel Access Control and Priority Handler, Monitor Channel Handler, Non-Auto Mode, Transparent Mode
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3086FV1.4XT
PEB3086FV14NP
PEB3086FV14XP
SP000007571
SP000007572
RFBS … Receive FIFO Block Size
Bit 6
0
0
1
1
Note: A change of RFBS will take effect after a transmitter command (CMDR.RMC,
SRA … Store Receive Address
0 … Receive Address isn’t stored in the RFIFOD
1 … Receive Address is stored in the RFIFOD
XCRC … Transmit CRC
0 … CRC is transmitted
1 … CRC isn’t transmitted
RCRC… Receive CRC
0 … CRC isn’t stored in the RFIFOD
1 … CRC is stored in the RFIFOD
ITF… Interframe Time Fill
Selects the inter-frame time fill signal which is transmitted between HDLC-frames.
0 … idle (continuous ’1’)
1 … flags (sequence of patterns: ‘0111 1110’)
Note: ITF must be set to ’0’ for power down mode.
Data Sheet
CMDR.RRES,) has been written
In applications with D-channel access handling (collision resolution), the only
possible inter-frame time fill is idle (continuous ’1’). Otherwise the D-channel on
the S/T-bus cannot be accessed
RFBS
Bit5
0
1
0
1
Block Size Receive FIFO
32 byte
16 byte
8 byte
4 byte
171
Detailed Register Description
PEB 3086
2003-01-30
ISAC-SX

Related parts for PEB 3086 F V1.4