3.6.3 Resolving Programmer Detection issues
If no programmers are detected, please check the following:
If multiple programmers are detected but some are not detected, please check the following:
ISPnano Series Programmer - User Manual – V1.11 – 12
To set EQTools to communicate with a particular programmer, simply click the radio button
next to the desired programmer in the list and then click <OK>
EQTools will now be set up to communicate with the attached programmer at the specified
address.
The serial cable is connected between the PC COM port and the programmer or the RS485
Converter.
All programmers are powered up.
All programmers have a unique ‘Node Address’.
The ‘RS485 Converter’ (if used) is powered on.
The RS485 cable is connected between the last detected programmer and the first non-
detected programmer.
Try swapping the RS485 cable for a known working cable just in case the cable is faulty.
Make sure each programmer has a unique ‘Node Address’. If more than one programmer
has the same address then this may cause ‘Communications Errors’.
th
May 2011