XW2Z-200J-B1 Omron, XW2Z-200J-B1 Datasheet - Page 340

no-image

XW2Z-200J-B1

Manufacturer Part Number
XW2Z-200J-B1
Description
CONNECTOR CABLE 2M
Manufacturer
Omron
Datasheet

Specifications of XW2Z-200J-B1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
XW2Z200JB1
Baud Rate
RS-232 Port Settings for No-protocol Communications (RS-232C)
Serial Communications Mode
Data Format
Baud Rate
Send Delay
System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
+161
+160
+160
+161
+162
Word
Word
Word
Word
Word
Address
Address
Address
Address
Address
00 to 07 00 hex: 9,600
08 to 11 03 hex: No-protocol
15
03
02
00 and
01
00 to 07 00 hex: 9,600
00 to 15 Send delay time,
Bits
Bits
Bits
Bits
Bits
06 hex: 9,600
07 hex: 19,200
08 hex: 38,400
09 hex: 57,600
Unit: bit/s
Default: 00 hex
Default: 00 hex
0: Default format
1: Custom
Default: 00 hex
0: 7-bit
1: 8-bit
Default: 0
0: 2 bits
1: 1 bit
Default: 0
00: Even
01: Odd
10: None
Default: 00 hex
01 hex: 300
02 hex: 600
03 hex: 1,200
04 hex: 2,400
05 hex: 4,800
06 hex: 9,600
07 hex: 19,200
08 hex: 38,400
09 hex: 57,600
Unit: bit/s
Default: 00 hex
0 to 99,990 ms
(0000 to 270F hex,
unit: 10 ms)
Default: 0000 hex
Settings
Settings
Settings
Settings
Settings
Only settings 00 hex and 06 to 09 hex
can be used in peripheral bus mode.
This setting determines whether the
RS-232C port will operate in No-proto-
col mode or another serial communica-
tions mode. Set 03 for No-protocol
Mode.
The standard settings are for 1 start bit,
7-bit data, even parity, 2 stop bits, and
9,600 baud.
Sets the data length.
Sets the number of stop bits.
Sets the parity.
This setting is valid when the RS-232C
port is set for the No-protocol Serial
Communications Mode. Set the Data
Format setting to 1 to enable this set-
ting.
When TXD(236) is executed, data will
be sent from the RS-232C port after the
delay time set here.
Function
Function
Function
Function
Function
A410.15 (RS-232C Port
Settings Changing Flag)
A410.15 (RS-232C Port
Settings Changing Flag)
A410.15 (RS-232C Port
Settings Changing Flag)
A410.15 (RS-232C Port
Settings Changing Flag)
A410.15 (RS-232C Port
Settings Changing Flag)
Related flags and
Related flags and
Related flags and
Related flags and
Related flags and
words
words
words
words
words
At next cycle (Also
can be changed
with STUP (237).)
At next cycle (Also
can be changed
with STUP (237).)
At next cycle (Also
can be changed
with STUP (237).)
At next cycle (Also
can be changed
with STUP (237).)
At next cycle (Also
can be changed
with STUP (237).)
Appendix C
When setting is
When setting is
When setting is
When setting is
When setting is
read
read
read
read
read
317