INT-1532L-5-M-000 TE Connectivity, INT-1532L-5-M-000 Datasheet - Page 38

DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V

INT-1532L-5-M-000

Manufacturer Part Number
INT-1532L-5-M-000
Description
DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V
Manufacturer
TE Connectivity
Datasheet

Specifications of INT-1532L-5-M-000

No. Of Digits / Alpha
4
Meter Function
Digital
Meter Range
0mA To 20mA
Digit Height
96mm
Supply Voltage Range
57.7V To 139V / 100V To 240V
Power Consumption
3W
Rohs Compliant
NA
Integra 1560 and 1580 Digital Transducer
Systems
Integra 1560 and 1580 multi-function transducers provide high accuracy
<0.2% measurement and communication of up to 50 major electrical and
power quality parameters, including true rms system values, power quality
data and total harmonic distortion (THD) measurement up to the 31st
harmonic. The range offers a 1560 DIN rail mounted version, and a 1580
variant featuring a base plate for surface mounting. Both transducers offer
the same high technical specifications and incorporate pulsed, analogue
and digital communication outputs. Transducers are fully programmable
through a Windows-based software configuration package, enabling
remote commissioning and monitoring via building management systems.
Alternatively, an optional menu driven display unit can be used
to configure and monitor up to 32 measured parameters. To suit user
requirements, the range includes single phase, single-phase 3-wire, 3-
phase 3-or 4-wire, and 3-phase 4-wire with neutral CT configurations.
Operation
The multi-function Integra 1560 and 1580 transducers offer uncomplicated operation and
high accuracy <0.2% measurement of three-phase voltage, current, frequency, watts, VAr,
VA, energy, power factor and total harmonic distortion measurement of both phase and
system, current and voltage.
3-phase 4-wire system line-to-line voltage measurements are usually derived from a
calculation of the vector of the line-to-neutral voltage measurements. However, Integra
1530 includes true measurement of both line-to-neutral, and line-to-line measurements,
ensuring accurate readings even under phase fault conditions.
A simple Windows-based software package is available to configure the transducer. Once
configured, simultaneous monitoring of up to 50 electrical and power quality variables can
be communicated into building management systems via pulsed, analogue or digital
communication options. Status may also be monitored through the software package
via a PC.
Alternatively, an optional menu driven display unit can be used to configure and monitor up
to 32 measured parameters including three-phase voltage and current, and system watts,
VAr, VA, power factor, energy and total harmonic distortion. This Integra Display unit can
be permanently panel mounted locally to the transducer, or simply connected at times
when configuration, adjustment and/or status information is required.
Accuracy
Integra transducers utilise true rms measurement techniques up to the 31st harmonic,
providing <0.2% accuracy. An exceptional tolerance to high harmonic frequencies is
achieved from a robust frequency detection method, which is able to lock the
fundamental frequency onto any phase. High integrity measurements are possible
where the system approximates CT current in the absence of voltage signals.
System Input
Designed for all low, medium and high-voltage switchgear and distribution systems,
the Integra 1560 and 1580 offer programmable VT and CT ratio capability. Direct
connected up to 480V ac with 5A CT inputs standard, and 1A CT inputs available as
an option.
Neutral CT Input Option
High harmonic environments can produce unexpected and dangerous neutral currents.
Traditional 3-phase systems are only able to calculate the vector of line-to-neutral
current measurements, which may not register the true reading. Integra 1530 offers a
3-phase 4-wire version with a neutral 4th CT allowing true neutral current
measurement and protection in high harmonic environments.
Features
Measurement and communication of
up to 50 electrical and power
parameters
High accuracy <0.2%
THD measurement and power
quality data
True rms measurement
Pulsed, analogue and digital outputs
Modbus, Johnson Controls, Lonworks
and Profibus interface options
Fully programmable VT and CT ratios
Configurable via software package
or menu driven interface
Benefits
Replaces multiple single function
transducers
DIN rail or base mounted options
Local or remote configuration
and monitoring via building
management systems
ANSI style local or remote LED
display option
Neutral CT input option
True 3 and 4-wire measurement
Monitoring, control and protection
of expensive power assets
Applications
Switchgear
Distribution systems
Control panels
Energy management
Building management
Utility power monitoring
Process control
Motor monitoring
Approvals
UL file no. E200300
CSA pending
IEC 1010 / BSEN 61010-1
37