INT-1532L-5-M-000 TE Connectivity, INT-1532L-5-M-000 Datasheet - Page 26

DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V

INT-1532L-5-M-000

Manufacturer Part Number
INT-1532L-5-M-000
Description
DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V
Manufacturer
TE Connectivity
Datasheet

Specifications of INT-1532L-5-M-000

No. Of Digits / Alpha
4
Meter Function
Digital
Meter Range
0mA To 20mA
Digit Height
96mm
Supply Voltage Range
57.7V To 139V / 100V To 240V
Power Consumption
3W
Rohs Compliant
NA
Programmable Parameters
Product Codes
Order Code Example
INT-1544-120-5-L-W
Integra 1540 3-phase 4-wire, 120V L-L (69.3 L-N) nominal voltage, 5A CT input,
12-48V dc auxiliary supply, with pulsed output option.
Parameter
Password
Primary current
VT primary
Demand integration time
Reset
Pulse output duration
Pulse rate divisors
RS 485 interface baud rate
RS 485 parity
Modbus address
Product code
INT-1544-***-5-*-option
INT-1543-***-5-*-option
Input voltage suffix ***
100
110
115
120
139
208
240
277
380
400
415
480
600
Auxiliary voltage suffix*
L
M
Communications options
M
W
Range
4-digit 0000-9999
Max 9999:5 (360MW max**)
400kV (360MW max**)
** maximum VT or CT ratios are limited so
that the combination of primary voltage and
current does exceed 360MW at 120% of
relevant inputs
8, 15, 20, 30 minutes
Max demand & active energy registers
60, 100, 200 milliseconds
1, 10, 100, 1000
2.4, 4.8, 9.6, 19.2 kB
Odd / even / no, 1 or 2 stop bits
1-247
Product configuration
Integra 1540 3-phase 4-wire 5A CT input
Integra 1540 3-phase 3-wire 5A CT input
100V L-L (57.7V L-N)
110V L-L (63.5V L-N)
115V L-L (66.4V L-N)
120V L-L (69.3V L-N)
139V L-L (80.2V L-N)
208V L-L (120V L-N)
240V L-L (139V L-N)
277V L-L (160V L-N)
380V L-L (220V L-N)
400V L-L (230V L-N)
415V L-L (240V L-N)
480V L-L (277V L-N)
600V L-L (346V L-N)
12-48V dc
100-250V ac/dc
RS485 Modbus RTU or Johnson
Controls Metasys NII
kWh pulsed output
Measurement, Display and
Communication
Integra 1540 offers configuration,
display and communication of up to 31
electrical and power quality parameters.
1. System volts
2. System volts THD %
3. Volts L1–N
4. Volts L1–L2
5. Volts line 1 THD %
6. Current L1
7. Current line 1 THD %
8. Neutral current
9. kVAr
10. kWh (7-digit resolution)
11. kVArh (7-digit resolution)
12. kW demand
13. kW maximum demand
System current
System kW
System current THD %
Volts L2–N
Volts L3–N
Volts L2–L3
Volts L3–L1
Volts line 2 THD %
Volts line 3 THD %
Current L2
Current L3
Current line 2 THD %
Current line 3 THD %
Frequency
Power factor
kVA
kW
Current demand
Current maximum demand
25