PSB2186N-V11TR Infineon Technologies, PSB2186N-V11TR Datasheet - Page 127

no-image

PSB2186N-V11TR

Manufacturer Part Number
PSB2186N-V11TR
Description
IC ISDN SUBSCRIB ACCESS 44-PLCC
Manufacturer
Infineon Technologies
Datasheet

Specifications of PSB2186N-V11TR

Controller Type
Subscriber Access Controller (ISDN)
Interface
4-Wire SPI Serial
Voltage - Supply
4.75 V ~ 5.25 V
Current - Supply
17mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
44-PLCC
Lead Free Status / RoHS Status
Request inventory verification / Request inventory verification
Other names
PSB2186N-V11INTR
PSB2186N-V11TR
Operational Description
F3 Power-Down
This is the deactivated state of the physical protocol. The receive line awake unit is active
except during an RST pulse. Clocks are disabled if SQXR:CFS=1. The power consumption in
this state is approximately 80 mW when the clock is running, and 8 mW otherwise.
F3 Power-Up
This state is identical to "F3 power-down", except for the C/I-output message. The state is
invoked by a C/I command TIM = "0000" (or IDP1 static low). After the subsequent activation
of the clocks the PU message is outputted. This occurs 0.5 ms to 4 ms after application of TIM,
depending on crystal capacitances.
F3 Pending Deactivation
The ISAC-S TE reaches this state after receiving INFO0 (from states F5 to F8) for 16 ms
(64
frames). This time constant is a "flywheel" to prevent accidental deactivation. From this state
an activation is only possible from the line (transition "F3 pend. deact." to "F5
unsynchronized"). A power-down state may be reached only after receiving DIU.
F4 Pending Activation
Activation has been requested from the terminal, INFO1 is transmitted, INFO0 is still received,
"Power-Up" is transmitted in the C/I channel. This state is stable: timer T3 (I.430) is to be
implemented in software.
F5 Unsynchronized
At the reception of any signal from the NT, the ISAC-S TE ceases to transmit INFO1 and awaits
identification of INFO2 or INFO4. This state is reached at most 50 s after a signal different
from INFO0 is present at the receiver of the ISAC-S TE.
F6 Synchronized
When the ISAC-S TE receives an activation signal (INFO2), it responds with INFO3 and waits
for normal frames (INFO4). This state is reached at most 6 ms after an INFO2 arrives at the
ISAC-S TE (when the oscillator was disabled in "F3 power-down").
F7 Activated
This is the normal active state with the layer-1 protocol activated in both directions. Note that
in IOM-2 mode the 2B+D channels can only be transmitted to the S/T interface if an "Activation
Request" command is written to the CIX0 register. From state "F6 synchronized", state F7 is
reached at most 0.5 ms after reception of INFO4. From state "F3 power-down" with the
oscillator disabled, state F7 is reached at most 6 ms after the ISAC-S TE is directly activated
by INFO4.
Semiconductor Group