72T6360L7-5BBI IDT, Integrated Device Technology Inc, 72T6360L7-5BBI Datasheet - Page 50

no-image

72T6360L7-5BBI

Manufacturer Part Number
72T6360L7-5BBI
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 72T6360L7-5BBI

Operating Supply Voltage (typ)
2.5V
Operating Supply Voltage (min)
2.375V
Operating Supply Voltage (max)
2.625V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
324
Lead Free Status / RoHS Status
Not Compliant
WIDTH EXPANSION CONFIGURATION
SFCs in width expansion to support bus-widths greater than 36-bits. This
configuration connects the input and output bus of two devices together to create
a wider bus. The read and write clocks for each device are driven with a clock
driver. The empty and full flags of both devices are connected to a logic gate
(AND/OR) depending on whether IDT Standard mode or FWFT mode is
selected. Because of the variation in skew between the read clock and write
NOTES:
1. Use an AND gate in IDT Standard mode, an OR gate in FWFT mode.
2. Do not connect any output signals directly together.
IDT72T6360 2.5V, SEQUENTIAL FLOW-CONTROL DEVICE
x9, x18, x36 BIT WIDE CONFIGURATION
The sequential flow-control (SFC) device can be connected with another
Clock Driver
IDT5T905
Clock Driver
IDT5T905
Gate
(1)
Full Flag/Input Ready
Figure 36. Width Expansion Configuration in IDT Standard Mode and FWFT Mode
Full Flag/Input Ready
Write Clock
Write Enable
Data Inputs
Write Clock
64
36
36
WCLK
WEN
FF / IR
Dn
WCLK
WEN
FF/IR
Dn
SFC
SFC
50
clock, it is possible for EF/FF deassertion and IR/OR assertion to vary from one
cycle between the devices. The logic gate connected to the status flags will create
a composite flag that will update the status of both SFC devices to represent a
more accurate status of the configuration. To minimize the skew between the
two write and read clocks, a clock driver (IDT5T905 recommended) is used
to drive the input clocks for both SFC devices. Figure 36 illustrates the width
expansion configuration.
RCLK
REN
EF / OR
Qn
RCLK
REN
EF/OR
Qn
36
36
Read Clock
Read Enable
Empty Flag/Output Ready
Data Outputs
Empty Flag/Output Ready
Read Clock
64
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES
6357 drw50
FEBRUARY 10, 2009
Clock Driver
IDT5T905
Clock Driver
IDT5T905
Gate
(1)