H7BX-A AC100-240 Omron, H7BX-A AC100-240 Datasheet - Page 4

1-stg 72x72 Multifunc Counter

H7BX-A AC100-240

Manufacturer Part Number
H7BX-A AC100-240
Description
1-stg 72x72 Multifunc Counter
Manufacturer
Omron
Datasheet

Specifications of H7BX-A AC100-240

Display Type
LCD Backlight
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
■ I/O Functions
● Using as a Counter (See note 1.)
Note 1. Refer to pages 14 to 17 for information on the operation of input and output functions.
4
Inputs
Outputs OUT1, 2
1-stage/2-stage preset counter Does not operate (Not used).
Total and preset counter
Batch counter
Dual counter
2. In increment mode or increment/decrement mode, the present value returns to 0; in decrement
3. The reset indicator will not be lit when the total reset or reset 2 input is ON.
mode, the present value returns to the set value with 1-stage models, and returns to set value 2 with
2-stage models.
CP1, CP2
Reset or
Reset 1
Total Reset
or Reset 2
Multifunction Counter
Function
(1) All Modes Except for Dual Counter Mode
(2) Dual Counter Mode
(1) All Modes Except for Dual Counter Mode
(2) Dual Counter Mode
The reset operation depends on the selected function. (See note 3.)
When the corresponding set value is reached, signals are output according to the
designated output mode.
Reads count signals.
Increment, decrement, up/down (command, individual, or quadrature) inputs
can be used.
Reads CP1 count signals on CP1 input and CP2 count signals on CP2 input.
Increment signals can be used.
Resets present value and outputs (OUT2 when using the batch counter). (See
note 2.)
Counting cannot be performed while resetting or when reset 1 input is ON.
The reset indicator is lit while the reset input is ON.
Resets the CP1 present value to 0.
Counting the CP1 input cannot be performed while the reset 1 input is ON.
The reset indicator is lit while the reset 1 input is ON.
Resets the total count value.
Holds the total count value at 0 while the total reset input is ON.
Resets the batch count value and batch output (OUT1).
Holds the batch count value at 0 while the reset 2 input is ON.
Resets the CP2 present value.
Counting for CP2 input is disabled while the reset 2 input is ON.
H7BX
Reset operation
● Using as a Tachometer
● Using as a Counter or
Note: For details, refer to page 24.
Inputs
Outputs OUT1, 2
Key protection
input
Tachometer
CP1,
CP2
Reset 1,
Reset 2
Reads counting signals.
(CP2 input is not
available.)
Outputs signals according
to the specified output
mode when a set value is
reached.
Prohibits using the keys
on the front panel.
Set the key protection
level in function selection
mode.
Holds the measurement
value and outputs.
(Reset 2 input is not
available.)
The reset indicator is lit
during hold.