Specifications
■ Ratings
Note 1. The total and preset counter functions as a 1-stage preset counter and total counter.
2
Item
Type
Supported configurations
Ratings
Mounting method
External connections
Degree of protection
Input signals
Counter
Tachom-
eter
Prescaling function
Decimal point adjustment
Sensor waiting time
Key protection input
Input method
(except key protection input)
External power supply
Control output
Display (See note 3.)
Digits
Memory backup
Ambient operating temperature
Ambient storage temperature
Ambient operating humidity
Case color
Accessories
2. Do not use an inverter output for the power supply.
3. Displayed only when the power is ON. Not displayed when the power is OFF.
Power supply voltage
(See note 2.)
Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption
Max. counting speed
Input modes
Output modes
One-shot output time
Reset input
Pulse measurement
method
Max. counting speed
Measuring ranges
Measuring accuracy
Output modes
Auto-zero time
Startup time
Average processing
Multifunction Counter
Model
Preset counter
1-stage preset counter, total and preset counter (See note
1.) (selectable)
H7BX-A/AW: 9.6 VA max. (100 to 240 VAC)
H7BX-AD1/AWD1: 8 VA max. (24 VAC), 5.3 W max. (12 to 24 VDC)
Flush mounting
Screw terminals
IP54 (front section only)
CP1, CP2, reset 1, reset 2, key protection
30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), setting for both CP1 and CP2
Increment, decrement, command (UP/DOWN A), individual (UP/DOWN B), quadrature (UP/DOWN C)
N, F, C, R, K-1, P, Q, A, K-2, D, L
0.01 to 99.99 s
External reset (minimum reset input signal width: 1 ms or 20 ms selectable), manual reset, and automatic reset (internal
according to C, R, P, and Q mode operation)
Yes (0.001 to 99.999)
Yes (rightmost 3 digits)
290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Response speed: Approx. 1 s
No-voltage NPN input (fixed)
Short-circuit (ON) impedance: 1 k max. (Leakage current at 0 : Approx. 12 mA)
Short-circuit (ON) residual voltage: 3 V max.
Open (OFF) impedance: 100 k min.
No-voltage NPN input or voltage PNP input (selectable)
No-voltage input
Voltage input
12 VDC ( 10%), 100 mA (For details, refer to External Power Supply on page 26.)
Contact output: 3 A at 250 VDC/30 VDC, resistive load (cos = 1)
Minimum applied load: 10 mA at 5 VDC (Failure level: P, reference value)
Transistor output: 100 mA max. at 30 VDC max.
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
Backlit 7-segment negative transmissive LCD
Character Heights
PV: 13.5 mm (red/green)
SV: 9 mm (green)
6 digits
EEPROM (Overwrites: 100,000 min.), Data storage: 10 years min.
25 to 85 C (with no condensation)
Black (N1.5)
Two flush-mounting adapters, terminal cover
Short-circuit (ON) impedance: 1 k max. (Leakage current at 0 : Approx. 12 mA)
Short-circuit (ON) residual voltage: 3 V max.
Open (OFF) impedance: 100 k min.
High level: 4.5 to 30 VDC
Low level: 0 to 2 VDC
Input resistance: Approx. 4.7 k
99,999 to 999,999 (5 digits negative and 6 digits positive)
10 to 55 C (with no icing)
25 to 65 C (with no icing)
100 to 240 VAC (50/60 Hz)
24 VAC (50/60 Hz)/12 to 24 VDC (ripple 20% max.)
H7BX
H7BX-A/AD1
---
---
---
---
---
---
---
---
Preset counter/tachometer
1-stage preset counter, 2-stage preset counter, total and
preset counter (See note 1.), batch counter, dual counter,
tachometer (selectable)
N, F, C, R, K-1, P, Q, A, K-2, D, L, H
Periodic measurement (Sampling period: 200 ms)
30 Hz or 10 kHz (selectable)
30 Hz: 0.01 to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
Upper and lower limits, area, upper limit, lower limit
0.1 to 99.9 s
0.0 to 99.9 s
OFF/2/4/8 times
6 digits
Counter: 99,999 to 999,999 (5 digits negative and 6 digits
positive)
Tachometer: 0 to 999,999 (6 digits)
Two flush-mounting adapters, terminal cover, DIP switch
setting stickers
0.1% FS 1 digit max. (at 23 5 C)
H7BX-AW/AWD1