H7BX-A AC100-240 Omron, H7BX-A AC100-240 Datasheet - Page 15

1-stg 72x72 Multifunc Counter

H7BX-A AC100-240

Manufacturer Part Number
H7BX-A AC100-240
Description
1-stg 72x72 Multifunc Counter
Manufacturer
Omron
Datasheet

Specifications of H7BX-A AC100-240

Display Type
LCD Backlight
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Note 1. When the present value reaches 999999, it returns to 0.
Output
mode
setting
2. Counting cannot be performed while the reset/reset 1 input is ON.
3. If reset/reset 1 input turns ON while the one-shot output is ON, one-shot output turns OFF.
4. If there is power failure while an output is ON, the output will turn ON again when the power supply has recovered.
5. Do not use the counter function in applications where the count may be completed (again) while the one-shot output is ON.
6. The set values are between 0 and 999999.
For a one-shot output, the output will turn ON again for the duration of the output time setting once the power supply has recovered.
Q
A
P
999999
Set
value 2
Set
value 1
Reset/
reset 1
OUT1
OUT2
999999
999999
Set
value 2
Set
value 1
Set
value 2
Set
value 1
Reset/
reset 1
OUT1
OUT2
Reset/
reset 1
OUT1
OUT2
0
0
0
UP
Input mode
DOWN
Multifunction Counter
Self-holding
UP/DOWN A, B, C
output
One-shot output from OUT1
Self-holding
output
One-shot output
from OUT2
H7BX
The present value display
does not change during the
one-shot output time
period, but the actual count
returns to the reset start
status.
The outputs return to the
one-shot start state and
repeat one-shot operation.
OUT1 self-holding output
turns OFF after the OUT2
one-shot output time.
The OUT1 one-shot output
time is independent of
OUT2.
The present value
continues to increase/
decrease for the one-shot
output time, but returns to
the reset start status after
the one-shot output time
has elapsed.
The outputs repeat one-
shot operation.
OUT1 self-holding output
turns OFF after the OUT2
one-shot output time.
The OUT1 one-shot output
time is independent of
OUT2.
The present value display
and OUT1 self-holding
output is held until reset/
reset 1 input turns ON.
OUT1 and OUT2 are
independent.
Operation after count
(The one-shot output time
can be set in the range
0.01 to 99.99s.)
completion
15