H7BX-A AC100-240 Omron, H7BX-A AC100-240 Datasheet - Page 24

1-stg 72x72 Multifunc Counter

H7BX-A AC100-240

Manufacturer Part Number
H7BX-A AC100-240
Description
1-stg 72x72 Multifunc Counter
Manufacturer
Omron
Datasheet

Specifications of H7BX-A AC100-240

Display Type
LCD Backlight
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
■ Key Protect Level
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by
specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/
OFF status of the key protect switch after the H7BX is mounted to the panel.
Note: Changing to configuration selection mode and function selection mode.
■ Self-diagnostic Function
The following displays will appear if an error occurs.
Note 1. Display flashes (1-second cycles).
24
(default setting)
2. Occurs when the present value or the total count value goes below 99,999
3. Occurs when the present value reaches 999,999 under the following conditions:
4. Except when the H7BX is used as a tachometer.
5. Includes the case where the EEPROM has reached its overwrite lifetime.
Main display
Level
KP-1
KP-2
KP-3
KP-4
KP-5
(See note 1.)
(See note 1.)
-----
fffff
The output mode is K-2, D, L, or H.
The H7BX is set for dual counter operation.
e1
e2
e2
Multifunction Counter
Sub-display
No change
No change
Meaning
Not lit
Not lit
sum
H7BX
Key protect indicator
Present value underflow
(See note 2.)
Present value overflow
(See note 3.)
CPU
Memory error (RAM)
Memory error (EEP)
(See note 5.)
Error
Changing mode
(See note.)
No
No
No
No
No
Output status
Switching display in
No change
No change
OFF
OFF
OFF
run mode
Yes
Yes
Yes
Yes
No
Details
Either press the Reset
Key or turn ON reset
input.
Either press the Reset
Key or turn ON reset
input. (See note 4.)
Either press the Reset
Key or reset the power
supply.
Reset the power supply.
Reset to the factory
settings using the Reset
Key.
Correction method
Reset Key
Yes
Yes
No
No
No
Set value after reset
(Up Keys for 6-digit
Up/Down Keys
No change
No change
No change
No change
models)
Yes
Yes
0
No
No
No

Related parts for H7BX-A AC100-240