When the H7BX using as a tachometer, switch to the tachometer configuration using the procedure given on page 23.
■ Settings for Advanced Functions
20
(See note 1.)
Settings that cannot be performed with the DIP switch are performed with the operation keys.
3 s min.
Power ON
Multifunction Counter
(See note 2.)
3 s min.
Tachometer
output mode
(TOTM)
Counting
speed
(CNTS)
Decimal
point
position
(DP)
Prescale
value
(PSCL)
Average
processing
(AVG)
Auto-zero
time
(AUTZ)
Startup
time
(STMR)
NPN/PNP
input mode
(IMOD)
Display
color
(COLR)
Key protect
level
(KYPT)
Note: 1. If the mode is switched to the function setting mode during operation, operation will
The characters displayed in reverse video are the initial values.
When performing settings with operation keys only, turn ON pin 1 of the DIP switch to OFF (factory setting). If
pin 1 of the DIP switch is ON, the setting items indicated by
For details on operations in run mode, refer to page 22.
Set the tachometer output mode with any of the
Set the counting speed with any of the
Set the decimal point position with any of the
Set the number for each digit with the
Set the average processing with any of the
Set the number for each digit with the
Set the number for each digit with the
Set the NPN/PNP input mode with any of the
Set the display color with any of the
Set the key protect level with any of the
H7BX
(No average
processing)
(0.1 s)
(0.0 s)
(HI-LO)
(No decimal
(0.001)
(30 Hz)
(NPN
input)
(Red)
(KP-1)
2. Changes made to settings in function setting mode are enabled for the first time when
point)
continue.
the mode is changed to run mode. Also, when settings are changed, the counter is
automatically reset (measured values initialized and outputs turned OFF) on returning
to run mode.
(Green)
(99.9 s)
(99.9 s)
measurements)
(PNP
input)
(10 kHz)
(AREA)
(1.000)
(Average
(KP-2)
of 2
after decimal
(One digit
(Red-green) (Green-red)
point)
measurements)
(99.999)
(HI-HI)
(KP-3)
(Average
of 4
after decimal
(Two digits
(LO-LO)
point)
(KP-4)
measurements)
Up
(Average
Up
Up
Up
of 8
Up
Keys.
Up
Keys.
Keys.
Keys.
Keys.
Up
Keys.
(KP-5)
Up
after decimal
Up
(Three digits
Keys.
Up
point)
Keys.
Keys.
Keys.
will not be displayed.