EP4CGX75DF27C7N Altera, EP4CGX75DF27C7N Datasheet - Page 405

no-image

EP4CGX75DF27C7N

Manufacturer Part Number
EP4CGX75DF27C7N
Description
Cyclone IV GX
Manufacturer
Altera
Series
CYCLONE® IV GXr

Specifications of EP4CGX75DF27C7N

Number Of Logic Elements/cells
73920
Number Of Labs/clbs
4620
Total Ram Bits
4257792
Number Of I /o
310
Number Of Gates
-
Voltage - Supply
1.16 V ~ 1.24 V
Mounting Type
*
Operating Temperature
0°C ~ 85°C
Package / Case
*
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CGX75DF27C7N
Manufacturer:
SONGCHUAN
Quantity:
1 000
Part Number:
EP4CGX75DF27C7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CGX75DF27C7N
Manufacturer:
ALTERA
0
Chapter 3: Cyclone IV Dynamic Reconfiguration
Dynamic Reconfiguration Modes
Figure 3–6. Write Transaction Waveform—Use the same control signal for all the channels Option
Note to
(1) In this waveform example, you want to write to only the transmitter portion of the channel.
© December 2010 Altera Corporation
Figure
rx_tx_duplex_sel [1:0]
3–6:
tx_vodctrl [2:0]
reconfig_clk
write_all
For example, assume the number of channels controlled by the dynamic
reconfiguration controller is two, tx_vodctrl_out is 6 bits wide.
Write Transaction
The value you set at the selected PMA control ports is written to all the transceiver
channels connected to the ALTGX_RECONFIG instance.
For example, assume you have enabled tx_vodctrl in the ALTGX_RECONFIG
MegaWizard Plug-In Manager to reconfigure the V
complete a write transaction to reconfigure the V
1. Before you initiate a write transaction, set the selected PMA control ports to the
2. Set the rx_tx_duplex_sel port to 2'b10 so that only the transmit PMA controls are
3. Ensure that the busy signal is low before you start a write transaction.
4. Assert the write_all signal for one reconfig_clk clock cycle. This initiates the
5. The busy output status signal is asserted high to indicate that the dynamic
Figure 3–6
Read Transaction
If you want to read the existing values from a specific channel connected to the
ALTGX_RECONFIG instance, observe the corresponding byte positions of the PMA
control output port after the read transaction is completed.
For example, if the number of channels controlled by the ALTGX_RECONFIG is two,
the tx_vodctrl_out is 6 bits wide. The tx_vodctrl_out[2:0] signal corresponds to
channel 1 and the tx_vodctrl_out[5:3] signal corresponds to channel 2.
busy
(1)
desired settings (for example, tx_vodctrl = 3'b001).
written to the transceiver channel.
write transaction.
reconfiguration controller is busy writing the PMA control values. When the write
transaction has completed, the busy signal goes low.
shows the write transaction for Method 2.
3'b111
2'b00
3'b001
2'b10
OD
OD
, perform the following steps:
of the transceiver channels. To
Cyclone IV Device Handbook, Volume 2
3–15

Related parts for EP4CGX75DF27C7N