Specifications of C500RM201

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Masters and Slaves
Switches
CONTINUE/STOP Switch
TEST
CONTINUE/STOP
This switch is used to set either CONTINUE or STOP mode to designate re-
sponse to transmission errors. When a transmission error occurs, data trans-
mission to Slaves will continue in CONTINUE mode and stop in STOP mode.
Transmission errors for Masters include BCC errors, no-Slave-response er-
rors, and transmission line check errors.
CONTINUE
STOP
Pressed to test the transmission line when the PC is in PROGRAM mode. Test
is repeatedly performed while button is held down. This switch is also pressed
to clear transmission errors.
Used to select whether or not transmission is to be STOP continued for trans-
mission errors or I/O bus errors at Slaves.
Communications with Slaves continued for transmission er-
rors. Normal operation continued after error cleared.
Communications with Slaves discontinued for transmission
errors. Refer to Section 5 Error Processing for recovery proce-
dure.
CONTINUE
STOP
Section 4-1
47