Description
NETWORK READ/WRITE Instructions
6-2-4 NETWORK READ - RECV(98)
Limitations
RECV(98)
D
C
S
Ladder Symbols
The ladder diagram programming symbols, operand names, and allowable
data areas for RECV(98) are shown below.
C through C+2 must be within the same data area and must be within the values
specified below.
When executed with an ON execution condition, RECV(88) transfers data
beginning at S from a node on the SYSMAC LINK System to words beginning at
D. The control words, beginning with C, provide the number of words to be
received, the source node, and other transfer parameters.
D + 0
D + 1
4. Indirectly Addressed Beginning Reception Flag:
Bit
The CV-series PC has a larger data area than the C-series PC. Therefore,
the beginning reception word of the destination node cannot be always des-
ignated by the operand of the SEND(90). If the beginning reception word
cannot be designated, set the indirectly addressed beginning reception flag
to 1 (ON: indirect addressing), in which case the second operand (D) will be
the indirect beginning reception word, and it will be possible to designate the
beginning reception word (rightmost word) of the destination node in BCD
with the word designated by the second operand (D).
This operation is possible with a C200HW-SLK13/14/23/24 SYSMAC LINK
Unit mounted in a C200HX, C200HG, C200HE, C200HS, or C200H PC
only.
Refer to the following table to designate the data area.
I/O (IR)
Link Relay (LR)
Holding Relay (HR)
Auxiliary Relay (AR)
Timer/Counter (T/C)
Data Memory (DM)
Destination node (C-series PC)
Word no. (fourth digit)
15 14 13 12
@RECV(98)
Area
Data area code
S
D
C
11
Word no. (third digit)
00
06
07
08
03
05
Data area
10
code
9
8
D: Destination beginning word
IR, SR, AR, DM, HR, TC, LR
S: Source beginning word
C: First control data word
Core I/O (CIO)
CPU Bus Link (G)
Auxiliary (A)
Timer (T)
Counter (C)
Data Memory (D)
Extended
Data
Data
Memory (E)
Operand Data Areas
IR, AR, DM, HR, TC, LR
IR, AR, DM, HR, TC, LR
0
7
Word no. (second
Destination node (CV-series PC)
0
6
digit)
0
5
Area
0
4
Banks 0 to 7
Current bank 18
Word no. (first digit)
3
Word no. (fifth digit)
2
Section 6-2
1
00
01
02
03
04
05
10 to 17
0
Data area
code
77