IS-C0203-F-E NKK Switches, IS-C0203-F-E Datasheet - Page 9

SMARTSWITCH CONTROLLER LCD

IS-C0203-F-E

Manufacturer Part Number
IS-C0203-F-E
Description
SMARTSWITCH CONTROLLER LCD
Manufacturer
NKK Switches
Datasheets

Specifications of IS-C0203-F-E

Accessory Type
Controller
Description/function
SMARTSWITCH Development Kit
For Use With/related Products
SmartSwitch™ Switches
For Use With
360-2345 - SWITCH COMPACT LCD 64X32 RGB360-2343 - SWITCH LCD 64X32 RGB360-2341 - DISPLAY LCD 64X32IS01BCEF - SMARTDISPLAY SUPER YEL/GRN LEDIS01BCE - SMARTDISPLAY SUPER YELLOW LEDIS15SBFP4B - SMARTSWITCH COMPACT WHITE LEDIS15SBCP4EF - SMARTSWITCH COMPACT YEL/GRN LEDIS15SACP4CF - SMARTSWITCH COMPACT RED/GRN LEDIS15ABFP4B - SMARTSWITCH STD BLK W/WHITE LEDIS15ABDP4B - SMARTSWITCH STD BLU W/WHITE LEDIS15ABDP4EG - SMARTSWITCH STD YELLOW/BLUE LEDIS15ABDP4E - SMARTSWITCH STD BLUE W/YEL LEDIS15ABCP4EF - SMARTSWITCH STD YEL/GRN LEDIS15ABCP4E - SMARTSWITCH STD LED YELLOWIS15AACP4CF - SMARTSWITCH STD YEL RED/GRN LED360-2334 - SMARTDISPLAY RED/GREEN/BLUE360-2333 - SMARTDISPLAY SUPER RED/GREEN LED360-2332 - SMARTSWITCH STANDARD RED/GRN/BLU360-2331 - SMARTSWITCH COMPACT RED/GRN/BLU360-2330 - SMARTSWITCH STD RED/GRN LED360-2329 - SMARTSWITCH COMPACT RED/GRN LED
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
360-2425
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
5. Communication Protocol
The controller communicates with the host by serial communication via RS232 (57.6K, 1 start bit, 8 bit, 1
stop bit). The controller receives the data via an interrupt routine that places the data on the circular receive
buffer. When the controller detects data in the circular receive buffer, at Step 5G, it reads one byte and
executes the following:
When the controller executes a subroutine and expects additional information:
Commands are one byte in the range of 20H to 2FH and 01H and are transmitted in hex format. The proper
format for all command options and data is specified for each command.
Commands to the controller
Command to reboot the controller
Command to check communication
Command to download a Legend block
A. If the byte is a command, the controller transmits a 61H and executes the subroutine for the command
B. If the byte is not a command, it is ignored.
A. A timer is set. If the expected data byte is not received in 50ms, the controller transmits 6EH and
B. If the byte value is not acceptable (invalid range, option, etc.), the controller transmits 6EH and
The command reboots the controller to power-up state.
The command is used to check if the controller is on-line.
The controller transmits back 61H to the host.
C0203 User Manual.doc
This command downloads a Legend block from the host to the EEPROM location.
and upon completion of command the controller transmits 79H. All of the commands are explained in
detail in this section.
terminates the routine.
terminates the routine.
command format:
transmit format:
command format:
transmit format:
command format:
transmit format:
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
C0203 Intelligent Controller User Manual
(xxH)
28H
(xxH)
(xxH)
24H
01H
www.nkkswitches.com • Email engineering@nkkswitches.com
[Address] [Legend Block]
(xxAH)
(xxAH)
Page 9 of 23