XBP24-PKI-001-RA Digi International/Maxstream, XBP24-PKI-001-RA Datasheet - Page 47

no-image

XBP24-PKI-001-RA

Manufacturer Part Number
XBP24-PKI-001-RA
Description
MODULE 802.15.4 RS-232 ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r

Specifications of XBP24-PKI-001-RA

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
0dBm
Sensitivity
-92dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Data Interface
Connector, Female DB-9
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Memory Size
-
Current - Transmitting
-
Other names
Q3255595
© 2008 Digi International, Inc. 
XBee‐PRO PKG‐R® RS‐232 RF Modem – 802.15.4 ‐ Product Manual v1.xAx 
RR (XBee Retries) Command
SC (Scan Channels) Command
SD (Scan Duration) Command
<Networking {Addressing}> The RR command is
used set/read the maximum number of retries
the modem will execute in addition to the 3
retries provided by the 802.15.4 MAC. For each
XBee retry, the 802.15.4 MAC can execute up to
3 retries.
This values does not need to be set on all modems for retries to work. If retries are enabled, the
transmitting modem will set a bit in the Digi RF Packet header which requests the receiving
modem to send an ACK (acknowledgement). If the transmitting modem does not receive an ACK
within 200 msec, it will re-send the packet within a random period up to 48 msec. Each XBee retry
can potentially result in the MAC sending the packet 4 times (1 try plus 3 retries). Note that retries
are not attempted for packets that are purged when transmitting with a Cyclic Sleep Coordinator.
<Networking {Association}> The SC command is
used to set and read the list of channels to scan
for all Active and Energy Scans as a bit field.
This affects scans initiated in command mode [AS
(Active Scan) and ED (Energy Scan) commands]
and during End Device Association and
Coordinator startup.
<Networking {Association}> The SD command is
used to set and read the exponent value that
determines the duration (in time) of a scan.
End Device (Duration of Active Scan during
Association) - In a Beacon system, set SD = BE of
the Coordinator. SD must be set at least to the
highest BE parameter of any Beaconing
Coordinator with which an End Device or
Coordinator wish to discover.
Coordinator - If the ‘ReassignPANID’ option is set on the Coordinator [refer to A2 parameter],
the SD parameter determines the length of time the Coordinator will scan channels to locate
existing PANs. If the ‘ReassignChannel’ option is set, SD determines how long the Coordinator will
perform an Energy Scan to determine which channel it will operate on.
Scan Time is measured as ((# of Channels to Scan) * (2 ^ SD) * 15.36ms). The number of
channels to scan is set by the SC command. The XBee RF Modem can scan up to 16 channels (SC
= 0xFFFF). The XBee PRO RF Modem can scan up to 12 channels (SC = 0x1FFE).
Examples: Values below show results for a 12‐channel scan  
If SD = 0, time = 0.18 sec
SD = 2, time = 0.74 sec
SD = 4, time = 2.95 sec
SD = 6, time = 11.80 sec
bit 0 - 0x0B
bit 1 - 0x0C
bit 2 - 0x0D
bit 3 - 0x0E
bit 4 - 0x0F
bit 5 - 0x10
bit 6 - 0x11
bit 7 - 0x12
SD = 8, time = 47.19 sec
SD = 10, time = 3.15 min
SD = 12, time = 12.58 min
SD = 14, time = 50.33 min
bit 8 - 0x13
bit 9 - 0x14
bit 10 - 0x15
bit 11 - 0x16
AT Command: ATRR
Parameter Range: 0 - 6
Default: 0
Minimum Firmware Version Required: 1.xA0
AT Command: ATSC
Parameter Range: 0 - 0xFFFF [Bitfield]
(bits 0, 14, 15 are not allowed when using the
XBee-PRO)
Default Parameter Value: 0x1FFE (all XBee-
PRO channels)
Related Commands: ED (Energy Scan), SD
(Scan Duration)
Minimum Firmware Version Required: v1.x80
AT Command: ATSD
Parameter Range: 0 - 0x0F
Default Parameter Value: 4
Related Commands: ED (Energy Scan), SC
(Scan Channel)
Minimum Firmware Version Required: v1.x80
bit 12 - 0x17
bit 13 - 0x18
bit 14 - 0x19
bit 15 - 0x1A