XBP24-PKI-001-RA Digi International/Maxstream, XBP24-PKI-001-RA Datasheet - Page 22

no-image

XBP24-PKI-001-RA

Manufacturer Part Number
XBP24-PKI-001-RA
Description
MODULE 802.15.4 RS-232 ANT
Manufacturer
Digi International/Maxstream
Series
XBEE-PRO™r

Specifications of XBP24-PKI-001-RA

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
0dBm
Sensitivity
-92dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Data Interface
Connector, Female DB-9
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Memory Size
-
Current - Transmitting
-
Other names
Q3255595
© 2008 Digi International, Inc. 
XBee‐PRO PKG‐R® RS‐232 RF Modem – 802.15.4 ‐ Product Manual v1.xAx 
4. RF Modem Configuration
4.1. Programming the RF Modem
4.1.1. Programming Examples
Refer to the ‘Command Mode’ section [p21] for more information about entering Command Mode,
sending AT commands and exiting Command Mode. For information regarding modem
programming using API Mode, refer to the ‘API Operation’ sections [p50].
Setup
Sample Configuration: Modify RF Modem Destination Address
Sample Configuration: Restore RF Modem Defaults
The programming examples in this section require the installation of Digi's X-CTU Software and
an RS-232 connection to a PC.
1.
2.
3.
NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch.
Ensure the ‘Baud’ setting on the ‘PC Settings’ tab matches the interface data rate of the RF
modem (by default, BD parameter = 3 (which corresponds to 9600 bps)).
Example: Utilize the X-CTU “Terminal” tab to change the RF modem's DL (Destination Address
Low) parameter and save the new address to non-volatile memory.
After establishing a serial connection between the RF modem and a PC [refer to the 'Setup' sec-
tion above], select the “Terminal” tab of the X-CTU Software and enter the following command
lines (‘CR’ stands for carriage return):
Method 1 (One line per command)
Method 2 (Multiple commands on one line)
Example: Utilize the X-CTU “Modem Configuration” tab to restore default parameter values.
After establishing a connection between the modem and a PC [refer to the 'Setup' section
above], select the “Modem Configuration” tab of the X-CTU Software.
1.
2.
Install Digi's X-CTU Software to a PC by double-clicking the "setup_X-CTU.exe" file. (The
file is located on the Digi CD and under the 'Software' section of the following web page:
www.maxstream.net/support/downloads.php). Refer to the the ‘X-CTU Software’ section
[p23] for more information.
Connect the RF modem to a PC using their respective serial ports.
Launch the X-CTU Software and select the 'PC Settings' tab. Verify the baud and parity set-
tings of the Com Port match those of the RF modem.
Select the 'Read' button.
Select the 'Restore' button.
Send AT Command
+++
ATDL <Enter>
ATDL1A0D <Enter>
ATWR <Enter>
ATCN <Enter>
Send AT Command
+++
ATDL <Enter>
ATDL1A0D,WR,CN <Enter>
System Response
OK <CR> (Enter into Command Mode)
{current value} <CR> (Read Destination Address Low)
OK <CR> (Modify Destination Address Low)
OK <CR> (Write to non-volatile memory)
OK <CR> (Exit Command Mode)
System Response
OK <CR> (Enter into Command Mode)
{current value} <CR> (Read Destination Address Low)
OK<CR> OK<CR> OK<CR>
     22