HD6417750SF167V Renesas Electronics America, HD6417750SF167V Datasheet - Page 799

MPU 3V 16K PB-FREE 208-QFP

HD6417750SF167V

Manufacturer Part Number
HD6417750SF167V
Description
MPU 3V 16K PB-FREE 208-QFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7750r
Datasheet

Specifications of HD6417750SF167V

Core Processor
SH-4
Core Size
32-Bit
Speed
167MHz
Connectivity
EBI/EMI, FIFO, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
28
Program Memory Type
ROMless
Ram Size
24K x 8
Voltage - Supply (vcc/vdd)
1.6 V ~ 2 V
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
208-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417750SF167V
Manufacturer:
INTERSIL
Quantity:
18 720
Part Number:
HD6417750SF167V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Serial Data Reception (Synchronous Mode): Figure 15.21 shows a sample flowchart for serial
reception.
Use the following procedure for serial data reception after enabling the SCI for reception.
When changing the operating mode from asynchronous to synchronous, be sure to check that the
ORER, PER, and FER flags are all cleared to 0. The RDRF flag will not be set if the FER or PER
flag is set to 1, and neither transmit nor receive operations will be possible.
No
No
Read receive data in SCRDR1,
Read ORER flag in SCSSR1
Read RDRF flag in SCSSR1
Clear RE bit in SCSCR1 to 0
and clear RDRF flag
All data received?
Start of reception
End of reception
in SCSSR1 to 0
Figure 15.21 Sample Serial Reception Flowchart (1)
RDRF = 1?
ORER = 1?
No
Yes
Yes
Error handling
Yes
Section 15 Serial Communication Interface (SCI)
Rev.7.00 Oct. 10, 2008 Page 713 of 1074
1. Receive error handling: If a
2. SCI status check and receive
3. Serial reception continuation
receive error occurs, read the
ORER flag in SCSSR1 , and
after performing the appropriate
error handling, clear the ORER
flag to 0. Transfer cannot be
resumed if the ORER flag is set
to 1.
data read: Read SCSSR1 and
check that the RDRF flag is set
to 1, then read the receive data
in SCRDR1 and clear the RDRF
flag to 0. Transition of the RDRF
flag from 0 to 1 can also be
identified by an RXI interrupt.
procedure: To continue serial
reception, finish reading the
RDRF flag, reading SCRDR1,
and clearing the RDRF flag to 0,
before the MSB (bit 7) of the
current frame is received. (The
RDRF flag is cleared
automatically when the direct
memory access controller
(DMAC) is activated by a
receive-data-full interrupt (RXI)
request and the SCRDR1 value
is read.)
REJ09B0366-0700

Related parts for HD6417750SF167V