HD6417020SX20IV Renesas Electronics America, HD6417020SX20IV Datasheet - Page 205

SH 1 CORE 32B MPU, 20MHZ/5V, 100

HD6417020SX20IV

Manufacturer Part Number
HD6417020SX20IV
Description
SH 1 CORE 32B MPU, 20MHZ/5V, 100
Manufacturer
Renesas Electronics America
Series
SuperH® SH7020r
Datasheet

Specifications of HD6417020SX20IV

Core Processor
SH-1
Core Size
32-Bit
Speed
20MHz
Connectivity
EBI/EMI, SCI
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
32
Program Memory Type
ROMless
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-
The DMA transfer request signals of table 9.4 are automatically withdrawn when the
corresponding DMA transfer is performed. If the cycle steal mode is being employed, the DMA
transfer request (interrupt request) will be cleared at the first transfer; if the burst mode is being
used, it will be cleared at the last transfer.
9.3.3
Channel Priority
When the DMAC receives simultaneous transfer requests on two or more channels, it selects a
channel according to a predetermined priority order. The three modes (fixed mode, round-robin
mode, and external-pin round-robin mode) are selected by the priority bits PR1 and PR0 in the
DMA operation register.
Fixed Mode: In these modes, the priority levels among the channels remain fixed. When PR1 and
PR0 bits are set 00, the priority order, high to low, is Ch. 0 > Ch. 3 > Ch. 2 > Ch. 1. When PR1
and PR0 bits are set 01, the priority order, high to low, is Ch. 1 > Ch. 3 > Ch. 2 > Ch. 0.
Round-Robin Mode: Each time one word or byte is transferred on one channel, the priority order
is rotated. The channel on which the transfer was just finished rotates to the bottom of the priority
order. When necessary, the priority order of channels other than the one that just finished the
transfer can also be shifted to keep the relationship between the channels from changing (figure
9.3). The priority order immediately after a reset is channel 0 > channel 3 > channel 2 > channel 1.
186 RENESAS