CDB4265 Cirrus Logic Inc, CDB4265 Datasheet - Page 41

BOARD EVAL FOR CS4265 CODEC

CDB4265

Manufacturer Part Number
CDB4265
Description
BOARD EVAL FOR CS4265 CODEC
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB4265

Main Purpose
Audio, CODEC
Embedded
No
Utilized Ic / Part
CS4265
Primary Attributes
Stereo, 24-Bit, 192 kHz Sample Rate
Secondary Attributes
Graphic User Interface, S/PDIF/ I2S / I2C / SPI Interface
Description/function
Audio CODECs
Operating Supply Voltage
5 V
Product
Audio Modules
For Use With/related Products
CS4265
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1001
DS657F2
6.11
6.11.1 Volume Control (Bits 7:0)
6.12
6.12.1 DAC Soft Ramp or Zero Cross Enable (Bits 7:6)
DACSoft
Vol7
7
7
DAC Channel B Volume Control - Address 0Bh
DAC Control 2 - Address 0Ch
Function:
The digital volume control allows the user to attenuate the signal in 0.5 dB increments from 0 to -127 dB.
The Vol0 bit activates a 0.5 dB attenuation when set, and no attenuation when cleared. The Vol[7:1] bits
activate attenuation equal to their decimal equivalent (in dB). Example volume settings are decoded as
shown in
Cross bits in the DAC Control 2 register (see
Function:
Soft Ramp Enable
Soft Ramp allows level changes, both muting and attenuation, to be implemented by incrementally ramp-
ing, in 1/8 dB steps, from the current level to the new level at a rate of 1 dB per 8 left/right clock periods.
See
Zero Cross Enable
Zero Cross Enable dictates that signal-level changes, either by attenuation changes or muting, will occur
on a signal zero crossing to minimize audible artifacts. The requested level change will occur after a time-
out period between 512 and 1024 sample periods (10.7 ms to 21.3 ms at 48 kHz sample rate) if the signal
does not encounter a zero crossing. The zero cross function is independently monitored and implemented
for each channel. See
Soft Ramp and Zero Cross Enable
Soft Ramp and Zero Cross Enable dictate that signal-level changes, either by attenuation changes or mut-
ing, will occur in 1/8 dB steps and be implemented on a signal zero crossing. The 1/8 dB level change will
occur after a time-out period between 512 and 1024 sample periods (10.7 ms to 21.3 ms at 48 kHz sam-
Table
DACZero
Vol6
Table
6
6
16.
15. The volume changes are implemented as dictated by the DACSoft and DACZero-
InvertDAC
Table
Table 15. Digital Volume Control Example Settings
Vol5
5
5
Binary Code
00000000
00000001
00101000
00101001
11111110
11111111
16.
Reserved
Vol4
4
4
Section
Reserved
Vol3
Volume Setting
6.12.1).
3
3
-127.5 dB
-20.5 dB
-127 dB
-0.5 dB
-20 dB
0 dB
Reserved
Vol2
2
2
Reserved
Vol1
1
1
CS4265
Reserved
Vol0
0
0
41