HD6417706 RENESAS [Renesas Technology Corp], HD6417706 Datasheet - Page 375

no-image

HD6417706

Manufacturer Part Number
HD6417706
Description
Renesas 32-Bit RISC Microcomputer Super RISC engine Family/SH7700 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417706
Manufacturer:
TDK
Quantity:
500
Part Number:
HD6417706
Manufacturer:
TOSH
Quantity:
1 000
Part Number:
HD6417706-SH3-133V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706BP133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706BP133V
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6417706F120DV
Manufacturer:
HITACHI
Quantity:
96
Part Number:
HD6417706F120DV
Manufacturer:
RENESAS/PBF
Quantity:
375
Part Number:
HD6417706F120DV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133V
Manufacturer:
EDISON
Quantity:
2 000
Part Number:
HD6417706F133V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
HD6417706F133V
Quantity:
27
13.3.3
The minute counter (RMINCNT) is an 8-bit read/write register used for setting/counting in the
BCD-coded minute section of the RTC. The count operation is performed by a carry for each
minute of the second counter.
The range of minute can be set is 00 to 59 (decimal). Errant operation will result if any other value
is set. Carry out write processing after halting the count operation with the START bit in RCR2.
RMINCNT is not initialized by a power-on reset or manual reset, or in standby mode.
13.3.4
The hour counter (RHRCNT) is an 8-bit read/write register used for setting/counting in the BCD-
coded hour section of the RTC. The count operation is performed by a carry for each 1 hour of the
minute counter.
The range of hour can be set is 00 to 23 (decimal). Errant operation will result if any other value is
set. Carry out write processing after halting the count operation with the START bit in RCR2.
RHRCNT is not initialized by a power-on reset or manual reset, or in standby mode.
Bit
7
6 to 4
3 to 0
Bit
7, 6
5, 4
3 to 0
Minute Counter (RMINCNT)
Hour Counter (RHRCNT)
Bit Name
Bit Name
Initial Value R/W
0
Initial Value R/W
All 0
R
R/W
R/W
R
R/W
R/W
Description
Always read as 0.
Counter for 10-unit of minute in the BCD-code. The
range can be set from 0 to 5 (decimal).
Counter for 1-unit of minute in the BCD-code.
The range can be set from 0 to 9 (decimal).
Description
Always read as 0.
Counter for 10-unit of hour in the BCD-code.
The range can be set from 0 to 2 (decimal).
Counter for 1-unit of hour in the BCD-code.
The range can be set from 0 to 9 (decimal).
Rev. 4.00, 03/04, page 329 of 660

Related parts for HD6417706