tmp89fm82t TOSHIBA Semiconductor CORPORATION, tmp89fm82t Datasheet - Page 407

no-image

tmp89fm82t

Manufacturer Part Number
tmp89fm82t
Description
8 Bit Microcontroller
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet
RA000
Table 22-9 Transfer Formats of the Flash Memory Read Command
BOOT
ROM
Note 1: "0xXX × 3" means that the device goes into an idle state after transmitting 3 bytes of 0xXX. For further information, refer
Note 2: For information on checksums, refer to "22.10 Checksum (SUM)". For information on passwords, refer to "22.12.1 Pass-
Note 3: If the area 0xFFE0 through 0xFFFF is all 0xFF, password authentication is not performed and, therefore, the password
Note 4: If the security program is enabled in flash memory or if a password error occurs, the TMP89FM82T stops communication,
Note 5: If a communication error occurs during the transfer of a password address or a password string, the TMP89FM82T stops
Note 6: If the number of bytes received at the m-th + 7 byte, m-th + 9 byte or m-th + 11 byte is more than 0x000000 or the size
m-th + 11 byte
m-th + 12 byte
m-th + 13 byte
:
n-th - 2 byte
n-th - 1 byte
n-th byte
n-th + 1 byte
Transfer byte
to Table 22-17.
words".
string need not be transmitted. The password count storage address and password comparison start address, however,
must be specified, even for a blank product. If the password count storage address and/or password comparison start
address are/is incorrect, a password error occurs; the TMP89FM82T stops communication and goes into an idle state.
Therefore, if a password error occurs, initialize the TMP89FM82T by using the RESET pin, and restart the serial PROM
mode.
and goes into an idle state. Therefore, if a password error occurs, initialize the TMP89FM82T by using the RESET pin,
and restart the serial PROM mode.
communication and goes into an idle state. Therefore, when a password error occurs, initialize the TMP89FM82T by using
the RESET pin, and restart the serial PROM mode.
of internal memory, the TMP89FM82T stops communication and goes into an idle state.
Number of bytes to read 07 to 00
-
-
(Wait for the next operation command data)
Transfer data from the external controller to
TMP89FM82T
Page 391
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate
Transfer data from TMP89FM82T to the ex-
-
OK: No data transmitted
Error: No data transmitted
Memory data
Memory data
OK: Checksum (high)
Error: No data transmitted
OK: Checksum (low)
Error: No data transmitted
-
ternal controller
TMP89FM82T

Related parts for tmp89fm82t