MT46V8M16TG-75Z Micron Technology Inc, MT46V8M16TG-75Z Datasheet - Page 80

MT46V8M16TG-75Z

Manufacturer Part Number
MT46V8M16TG-75Z
Description
Manufacturer
Micron Technology Inc
Type
DDR SDRAMr
Datasheet

Specifications of MT46V8M16TG-75Z

Organization
8Mx16
Density
128Mb
Address Bus
14b
Access Time (max)
750ps
Maximum Clock Rate
266MHz
Operating Supply Voltage (typ)
2.5V
Package Type
TSOP
Operating Temp Range
0C to 70C
Operating Supply Voltage (max)
2.7V
Operating Supply Voltage (min)
2.3V
Supply Current
140mA
Pin Count
66
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / Rohs Status
Not Compliant
POWER-DOWN (CKE Not Active)
PDF: 09005aef816fd013/Source: 09005aef82a95a3a
DDR_x4x8x16_Core2.fm - 128Mb DDR: Rev. F; Core DDR: Rev. A 4/07 EN
Unlike SDR SDRAMs, DDR SDRAMs require CKE to be active at all times an access is in
progress, from the issuing of a READ or WRITE command, until completion of the
access. Thus a clock suspend is not supported. For READs, an access completion is
defined when the read postamble is satisfied; for WRITEs, when the write recovery time
(
Power-down, as shown in Figure 53, is entered when CKE is registered LOW and all
criteria in Table 30 on page 38 are met. If power-down occurs when all banks are idle,
this mode is referred to as precharge power-down; if power-down occurs when a row is
active in any bank, this mode is referred to as active power-down. Entering power-down
deactivates the input and output buffers, excluding CK, CK#, and CKE. For maximum
power savings, the DLL is frozen during precharge power-down mode. Exiting power-
down requires the device to be at the same voltage and frequency as when it entered
power-down. However, power-down duration is limited by the refresh requirements of
the device (
While in power-down, CKE LOW and a stable clock signal must be maintained at the
inputs of the DDR SDRAM, while all other input signals are “Don’t Care.” The power-
down state is synchronously exited when CKE is registered HIGH (in conjunction with a
NOP or DESELECT command). A valid executable command may be applied one clock
cycle later.
t
WR) is satisfied.
t
REFC).
80
Micron Technology, Inc., reserves the right to change products or specifications without notice.
128Mb: x4, x8, x16 DDR SDRAM
©2004 Micron Technology, Inc. All rights reserved.
Operations

Related parts for MT46V8M16TG-75Z