82P2284BB IDT, Integrated Device Technology Inc, 82P2284BB Datasheet - Page 291

no-image

82P2284BB

Manufacturer Part Number
82P2284BB
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 82P2284BB

Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
82P2284BB
Manufacturer:
IDT
Quantity:
6
Part Number:
82P2284BBG
Manufacturer:
NS/TI
Quantity:
5 705
E1 FGEN Maintenance 0 (06BH, 16BH, 26BH, 36BH)
TS16LOS:
TS16AIS:
MFAIS:
TS16 of Frame 0 of the Signaling Multi-Frame).
G706RAI:
AUTOYELLOW:
REMAIS:
Programming Information
IDT82P2284
Bit Name
= 0: Normal operation.
= 1: The data stream to be transmitted on TS16 is overwritten with all zeros.
= 0: Normal operation.
= 1: The data stream to be transmitted on TS16 is overwritten with all ‘One’s.
This bit is valid when the Signaling Multi-Frame is generated. The value in this bit will be continuously transmitted in the Y bit position (the Bit 6 of
This bit is valid when the Basic frame is generated. It selects the criteria for automatic RAI transmission.
= 0: The RAI is transmitted automatically when: 1). out of Basic frame sync is declared in the receive path; 2). the receive path is operated in CRC-
4 to non-CRC-4 inter-working mode; 3). the offline searching in the receive path is out of Basic Frame sync; 4). the REMAIS bit (b0, E1-06BH,...) is
1.
= 1: The RAI is transmitted automatically when: 1). out of Basic frame sync is declared in the receive path; 2). the REMAIS bit (b0, E1-06BH,...) is
1.
This bit is valid when the Basic frame is generated.
= 0: Disable the automatic RAI transmission.
= 1: The Remote Alarm Indication (RAI) is automatically transmitted as logic 1 in the A bit position when conditions meet the criteria selected by the
G706RAI bit (b2, E1-06BH,...).
This bit is valid when the Basic frame is generated.
= 0: Disable the manual RAI transmission.
= 1: The Remote Alarm Indication (RAI) is manually transmitted as logic 1 in the A bit position.
Default
Bit No.
Type
7
Reserved
6
TS16LOS
R/W
5
0
TS16AIS
R/W
4
0
291
QUAD T1/E1/J1 LONG HAUL / SHORT HAUL TRANSCEIVER
MFAIS
R/W
3
0
G706RAI
R/W
2
0
AUTOYELLOW
R/W
1
0
February 25, 2008
REMAIS
R/W
0
0

Related parts for 82P2284BB