EVAL-AD1954EB Analog Devices Inc, EVAL-AD1954EB Datasheet - Page 27

no-image

EVAL-AD1954EB

Manufacturer Part Number
EVAL-AD1954EB
Description
BOARD EVAL FOR AD1954
Manufacturer
Analog Devices Inc
Datasheet

Specifications of EVAL-AD1954EB

Rohs Status
RoHS non-compliant
The format of the captured data varies according to the register
select fields. Data captured from the mult_out setting is in 1.23
twos complement format so that a full-scale input signal will
produce a full-scale digital output (assuming no processing). If
the parameters are set such that the input-to-output gain is more
than 0 dB, then the digital output will be clipped.
Data captured from the DB_OUT setting is in 5.19 format, where
the actual rms dB level is equal to –87 + (3  DB_OUT). In this
equation, DB_OUT is the value that is captured. It follows that in
this data format, the actual output readings will range from –87 dB
to +9 dB. The AD1954 uses the convention that 0 dB is the rms
value of the full-scale digital signal.
Data captured using the MDI setting is in 3.21 format. A 0 dB
digital input will produce a –12 dB digital output, assuming the
AD1954 is set for no processing.
Data captured using the MCI setting is in 2.20 format. This data
is generally a signal gain or filter coefficient, and therefore it does
not make sense to talk about the input-to-output gain. A coeffi-
cient of 01000000000000000000 corresponds to a gain of 1.0.
The data that must be written to set up the data capture is a
concatenation of the 9-bit program count index with the 2-bit
register select field. Refer to Table XX to find the capture count
and register select numbers that correspond to the desired point
to be monitored in the default signal processing flow.
REV. A
DB_OUT is the value that is captured. It follows that in
DB_OUT
DB_OUT setting is in 5.19 format, where
DB_OUT
DB_OUT). In this
DB_OUT
–27–
The SPI capture registers can be accessed by reading from SPI
Locations 261 (for SPI Capture Register 1) or 262 (for SPI Cap-
ture Register 2).The other two data capture registers (data capture
serial out) automatically transfer their data to the data capture
serial out (DCSOUT) pin. DCSOUT Capture Register 1 is pres-
ent in the left data slot (as defined by the serial input format), and
DCSOUT Capture Register 2 is present in the right data slot.The
format for writing to the SPI data capture setup registers is given
in the SPI section of this data sheet.
dB LEVEL METERS
Figure 19. Typical Application of Data Capture Feature
CONTROLLER
MICRO-
LRCLK
BCLK
AD1954
EXT DACs
DCSOUT
AD1954
CHANNEL
OUTPUT