RDK-142 Power Integrations, RDK-142 Datasheet - Page 32

KIT REF DESIGN TOP HX FOR TOP258

RDK-142

Manufacturer Part Number
RDK-142
Description
KIT REF DESIGN TOP HX FOR TOP258
Manufacturer
Power Integrations
Series
TOPSwitch®-HXr
Datasheet

Specifications of RDK-142

Mfg Application Notes
TOPSwitch-HX Family Appl Note
Main Purpose
AC/DC, Primary Side
Outputs And Type
2, Non-Isolated
Power - Output
35W
Voltage - Output
5V, 12V
Current - Output
2.2A, 2A
Voltage - Input
90 ~ 265VAC
Regulator Topology
Flyback
Frequency - Switching
30kHz
Board Type
Fully Populated
Utilized Ic / Part
TOP258
Product
Accessories & Kits
Silicon Manufacturer
Power Integrations
Kit Application Type
Displays
Application Sub Type
LCD Monitor
Kit Contents
Samples, Fully Functional Reference Board And Complete Documentation
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
596-1193
Figure 22 – 12 V Output in Response to 5 V
Note: 5 V Output maintained at full load.
(Waveshape is combination of line ripple and
transient response - see Figure 26)
11.5 Output Over-voltage Protection
The figures below show the performance of the output overvoltage protection circuit when
the control loop was opened.
Figure 24 – 5 V Output in Response to Open Loop
Note: 12 V Output maintained at no load.
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Transient, 90 VAC, 75-100-75%
Load Step.
Output Voltage 50 mV/div.
Output Current 1 A / div, 10 ms / div.
R5 = 5.1 kΩ to Configure Hysteretic
Shutdown.
Output Voltage 2 V/div, 1 s / div.
Figure 23 – 12 V Output in Response to 5 V
Note: 5 V Output maintained at full load.
Figure 25 – 5 V Output in Response to Open Loop
Note: 12 V Output maintained at no load.
Transient, 265 VAC, 75-100-75%
Load Step.
Output Voltage 50 mV/div.
Output Current 1 A / div, 10 ms / div.
R5 = 20 Ω to Configure Latching
Shutdown.
Output Voltage 2 V/div, 1 s / div.
Page 32 of 40