RDK-142 Power Integrations, RDK-142 Datasheet - Page 31

KIT REF DESIGN TOP HX FOR TOP258

RDK-142

Manufacturer Part Number
RDK-142
Description
KIT REF DESIGN TOP HX FOR TOP258
Manufacturer
Power Integrations
Series
TOPSwitch®-HXr
Datasheet

Specifications of RDK-142

Mfg Application Notes
TOPSwitch-HX Family Appl Note
Main Purpose
AC/DC, Primary Side
Outputs And Type
2, Non-Isolated
Power - Output
35W
Voltage - Output
5V, 12V
Current - Output
2.2A, 2A
Voltage - Input
90 ~ 265VAC
Regulator Topology
Flyback
Frequency - Switching
30kHz
Board Type
Fully Populated
Utilized Ic / Part
TOP258
Product
Accessories & Kits
Silicon Manufacturer
Power Integrations
Kit Application Type
Displays
Application Sub Type
LCD Monitor
Kit Contents
Samples, Fully Functional Reference Board And Complete Documentation
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
596-1193
11.4 Load Transient Response (75% to 100% Load Step)
In the figures shown below, signal averaging was used to better enable viewing of the
load transient response. The oscilloscope was triggered using the load current step as a
trigger source. Since the output switching and line frequency occur essentially at random
with respect to the load transient, contributions to the output ripple from these sources
will average out, leaving the contribution only from the load step response.
Figure 20 – 5 V Transient Response, 90 VAC,
Note
Page 31 of 40
:
12 V Output maintained at full load.
75-100-75% Load Step.
Output Voltage 20 mV/div.
Output Current 1 A / div, 10 ms / div.
Figure 21 – 5 V Transient Response, 265 VAC,
Note
:
Tel: +1 408 414 9200 Fax: +1 408 414 9201
12 V Output maintained at full load.
75-100-75% Load Step.
Output Voltage 20 mV/div.
Output Current 1 A / div, 10 ms / div.
Power Integrations
www.powerint.com

Related parts for RDK-142