CDB5376 Cirrus Logic Inc, CDB5376 Datasheet - Page 30

EVALUATION BOARD FOR CS5376

CDB5376

Manufacturer Part Number
CDB5376
Description
EVALUATION BOARD FOR CS5376
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB5376

Main Purpose
Seismic Evaluation System
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
CS3301A, CS3302A, CS4373A, CS5372A, CS5376A
Primary Attributes
Quad Digital Filter
Secondary Attributes
Graphical User Interface, SPI™ & USB Interfaces
Processor To Be Evaluated
CS330x, CS4373A, CS537x
Interface Type
USB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Contains lead / RoHS non-compliant
Other names
598-1778
10. TERMINOLOGY
30
relative accuracy =
Signal-to-Noise Ratio (Dynamic Range) - Ratio of the rms magnitude of the full-scale signal to the integrated
rms noise from DC to 430 Hz. The following formula is used to calculate SNR:
Total Harmonic Distortion - Ratio of the power of the fundamental frequency to the sum of the powers of all
harmonic frequencies from DC to 430 Hz. The following formula is used to calculate THD:
Full-scale Bandwidth - The bandwidth in which the converter can generate a full-scale signal while maintaining
performance specifications.
Impulse Amplitude - The maximum amplitude of the output signal beyond the full-scale bandwidth.
Differential Output Level - The voltage between the analog output pins of the device.
Full-scale Accuracy - Variation in the measured output voltage from the theoretical full-scale output voltage at
1x attenuation. The following formula is used to calculate full-scale accuracy:
Relative Accuracy - Variation in the measured output voltage from the theoretical attenuated output voltage at
each of the attenuation ranges. The following formula is used to calculate relative accuracy:
Full Scale Drift - The variation of the measured full-scale voltage across the specified temperature range.
Common Mode Drift - The variation in the measured common mode voltage across the specified temperature
range.
full scale accuracy =
|
(
theoretical attenuated voltage (relative to the measured full scale voltage)
THD = 10log
|
SNR = 20log
(
measured attenuated voltage - theoretical attenuated voltage
measured full scale voltage - theoretical full scale voltage
(
sum of the powers of the harmonic frequencies
(
rms magnitude of full scale signal
rms magnitude of noise floor
power of the fundamental frequency
theoretical full scale voltage
(
(
CS4373A
(
(
•100%
DS699F2
•100%
|
|

Related parts for CDB5376