KP-FSD3 Panduit Corp, KP-FSD3 Datasheet - Page 806

KIT FERRULE INS DIN AWG12-6

KP-FSD3

Manufacturer Part Number
KP-FSD3
Description
KIT FERRULE INS DIN AWG12-6
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule Kitr
Datasheet

Specifications of KP-FSD3

Kit Type
Ferrule - Wire End
Values
100 pcs - Assorted Insulated 12 ~ 6 AWG Ferrules
Kit Contents
50 Pieces Of FSD81-10, 20 Pieces Each Of FSD82-12 And FSD83-12, 10 Pieces Of FSD84-12
Mounting Method
Crimp
Where Used
To terminate stranded wire for insertion into terminal blocks
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Management
Identification
Accessories
Connectors
Connectors
& Write-On
Protection
Grounding
Pre-Printed
Cable Ties
Terminals
Permanent
Solutions
Overview
Steel Ties
Lockout/
& Safety
Stainless
Raceway
Abrasion
Labeling
Systems
Markers
Tagout
System
Surface
Wiring
Power
Labels
Index
Cable
Cable
D3.20
Duct
E5.
B1.
B2.
B3.
C1.
C2.
C3.
C4.
D1.
D2.
D3.
E1.
E2.
E3.
E4.
A.
F.
Type SP1
• For grounding one copper code conductor to steel structures,
• Made from high copper content, hard drawn copper rod provides
• Offered with standard and long stud lengths to accommodate a
• Wide wire range-taking capability minimizes inventory requirements
busbars, or transformers or for tapping from busbar with hex
nut and washer
high strength
variety of mounting applications
Service Post Connector, Male Stud, Single Conductor, Bronze
*UNC threads.
Part Number
SP1-8-C
SP1-8L-C
SP1-7-C
SP1-7L-C
SP1-4-C
SP1-4L-C
SP1-3-C
SP1-3L-C
SP1-2-C
SP1-2L-C
SP1-1/0-L
SP1-1/0L-L
SP1-2/0-Q
SP1-2/0L-Q
SP1-4/0-Q
SP1-4/0L-Q
SP1-350-12
SP1-350L-12
SP1-500-12
SP1-500L-12
ELECTRICAL SOLUTIONS
250 kcmil – 500 kcmil
4/0 STR – 350 kcmil
#12 SOL – #8 STR
#10 SOL – #4 STR
3/0 SOL – 4/0 STR
#6 SOL – 1/0 STR
#1 SOL – 2/0 STR
#8 SOL – #7 STR
#6 SOL – #3 STR
#4 STR – #2 STR
Conductor Size
Range
• True hex design for body and nut hex provides correct fit with
• Pressure bar provides secure connection on a full range of
• UL Listed for grounding and bonding and suitable for direct
socket, box, or open end wrenches resulting in proper torquing
of electrical connection
conductor combinations used with each connector providing
premium wire pull-out strength
burial in earth or concrete
Z
L
5/16 – 18
1/4 – 20
1/4 – 20
3/8 – 16
3/8 – 16
1/2 – 13
1/2 – 13
5/8 – 11
5/8 – 11
3/4 – 10
Size*
Stud
Figure Dimensions
(16.0)
(16.0)
(22.4)
(22.4)
(23.9)
(23.9)
(26.9)
(26.9)
(26.9)
(26.9)
(33.3)
(33.3)
(36.6)
(36.6)
(42.9)
(42.9)
(50.8)
(50.8)
(58.7)
(58.7)
0.63
0.63
0.88
0.88
0.94
0.94
1.06
1.06
1.06
1.06
1.31
1.31
1.44
1.44
1.69
1.69
2.00
2.00
2.31
2.31
L
In. (mm)
(12.7)
(25.4)
(12.7)
(25.4)
(14.2)
(25.4)
(28.7)
(28.7)
(19.1)
(31.8)
(19.1)
(31.8)
(25.4)
(38.1)
(25.4)
(38.1)
(35.1)
(44.5)
0.50
1.00
0.50
1.00
0.56
1.00
0.63
1.13
0.63
1.13
0.75
1.25
0.75
1.25
1.00
1.50
1.00
1.50
1.38
1.75
(16)
(16)
Z
Prime items appear in BOLD.
0.50
0.69
0.75
0.81
0.88
1.00
1.13
1.38
1.50
1.81
Hex
(In.)
Nut
Body
0.38
0.50
0.56
0.63
0.69
0.75
0.88
1.13
1.25
1.50
Hex
(In.)
Pkg.
Std.
Qty.
100
100
100
100
100
50
25
25
12
12