KP-FSD3 Panduit Corp, KP-FSD3 Datasheet - Page 762

KIT FERRULE INS DIN AWG12-6

KP-FSD3

Manufacturer Part Number
KP-FSD3
Description
KIT FERRULE INS DIN AWG12-6
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule Kitr
Datasheet

Specifications of KP-FSD3

Kit Type
Ferrule - Wire End
Values
100 pcs - Assorted Insulated 12 ~ 6 AWG Ferrules
Kit Contents
50 Pieces Of FSD81-10, 20 Pieces Each Of FSD82-12 And FSD83-12, 10 Pieces Of FSD84-12
Mounting Method
Crimp
Where Used
To terminate stranded wire for insertion into terminal blocks
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Management
Identification
Accessories
Connectors
Connectors
& Write-On
Protection
Grounding
Pre-Printed
Cable Ties
Terminals
Permanent
Solutions
Overview
Steel Ties
Lockout/
& Safety
D2.140
Stainless
Raceway
Abrasion
Labeling
Systems
Markers
Tagout
System
Surface
Wiring
Power
Labels
Index
Cable
Cable
Duct
E5.
B1.
B2.
B3.
C1.
C2.
C3.
C4.
D1.
D2.
D3.
E1.
E2.
E3.
E4.
A.
F.
For Use with Stranded Copper Code Conductors
Type CO
• Made from high strength electrolytic copper to provide premium
• Wide wire range-taking capability minimizes inventory
• Internal pressure bar and V-bottom collar provide uniform clamping
◆ CO650-12-3Y
electrical and mechanical performance
requirements
force on conductor to assure positive contact between conductor
and connector
**Uses slotted head set screw.
◆NEMA hole sizes and spacing.
Part Number
CO35-36-QY
CO70-14-QY
CO125-14-QY
CO225-56-QY
CO300-38-3Y
CO400-38-3Y
Two-Hole, Offset Floating Tongue Lug
Copper Conductor Size Range
(1) #10 AWG with (1) #12 AWG,
(1) #12 AWG with (1) #14 AWG
(1) #8 AWG with (1) #4 AWG,
(1) #8 AWG with (1) #6 AWG
(2) #10 AWG, (2) #12 AWG,
600 kcmil – 1000 kcmil
#14 AWG – #6 AWG,
#12 AWG – #1 AWG,
1/0 AWG – 500 kcmil
#1 AWG – 350 kcmil
#2 AWG – 1/0 AWG
#6 AWG – 4/0 AWG
(2) #14 AWG,
Current
(Amps)
Rating
ELECTRICAL SOLUTIONS
125
225
300
400
650
50
90
Stud Hole
Size
(In.)
3/16
5/16
1/4
1/4
3/8
3/8
1/2
• Inspection window to visually assure full conductor insertion
• Plated steel set screw provides high strength, durable electrical
• cULus Listed and CSA Certified for use up to 600 V
• Available with NEMA hole sizes and spacing
H
Stud Hole
contact between conductor and connector
Spacing
1.00
1.00
1.00
1.00
1.87
1.75
1.75
(In.)
M
Hex Size
3/16
5/16
5/16
(In.)
L
3/8
**
**
**
SPACING
HOLE
P
2.19
2.50
2.97
3.62
5.69
6.00
6.25
T
L
W
0.38
0.50
0.63
1.00
1.00
1.50
2.00
W
Figure Dimensions
0.49
0.64
0.88
1.13
1.39
1.61
2.32
H
(In.)
Prime items appear in BOLD.
0.07
0.09
0.13
0.13
0.19
0.19
0.25
T
1.46
1.60
1.87
2.28
3.99
3.79
3.68
P
0.43
0.50
0.60
0.94
1.23
1.41
1.85
M
Pkg.
Std.
Qty.
25
25
25
25
3
3
3