KP-FSD3 Panduit Corp, KP-FSD3 Datasheet - Page 766

KIT FERRULE INS DIN AWG12-6

KP-FSD3

Manufacturer Part Number
KP-FSD3
Description
KIT FERRULE INS DIN AWG12-6
Manufacturer
Panduit Corp
Series
Pan-Term®r
Type
Ferrule Kitr
Datasheet

Specifications of KP-FSD3

Kit Type
Ferrule - Wire End
Values
100 pcs - Assorted Insulated 12 ~ 6 AWG Ferrules
Kit Contents
50 Pieces Of FSD81-10, 20 Pieces Each Of FSD82-12 And FSD83-12, 10 Pieces Of FSD84-12
Mounting Method
Crimp
Where Used
To terminate stranded wire for insertion into terminal blocks
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Management
Identification
Accessories
Connectors
Connectors
& Write-On
Protection
Grounding
Pre-Printed
Cable Ties
Terminals
Permanent
Solutions
Overview
Steel Ties
Lockout/
& Safety
D2.144
Stainless
Raceway
Abrasion
Labeling
Systems
Markers
Tagout
System
Surface
Wiring
Power
Labels
Index
Cable
Cable
Duct
E5.
B1.
B2.
B3.
C1.
C2.
C3.
C4.
D1.
D2.
D3.
E1.
E2.
E3.
E4.
A.
F.
For Use with Stranded Aluminum or Copper Code Conductors
Type LAM2SB
• Dual barrel provides termination of two conductors
• Vertical configuration saves space
• Made from high strength, extruded aluminum alloy to provide
• Tin-plated to inhibit corrosion
• Wide wire range-taking capability minimizes inventory requirements
The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155.
*UL Listed and CSA Certified.
For Use with Stranded Aluminum or Copper Code Conductors
Type LAM3B
• Triple barrel provides termination of three conductors
• Made from high strength, extruded aluminum alloy to provide
• Tin-plated to inhibit corrosion
• Wide wire range-taking capability minimizes inventory requirements
• Inspection window to visually assure full conductor insertion
• Plated steel or aluminum set screw provides high strength, durable
◆ LAM3B3/0-12-3Y
◆ LAM3B250-12-1Y
◆ LAM3B350-12-1Y
◆ LAM3LB600-12-1
◆ LAM3LB1000-121Y
Part Number
LAM2SB600-38-1Y*
LAM2SB750-38-1Y*
LAM2SSB500-141Y
premium electrical and mechanical performance
premium electrical and mechanical performance
electrical contact between conductor and connector
The use of Panduit oxide inhibiting joint compound (CMP-100) is recommended for pad to pad and conductor connections. See page D2.155.
**Uses slotted head set screw.
◆NEMA hole sizes and spacing.
Part Number
LAM3B1/0-38-6Y
Two-Hole, Vertical Two-Barrel Lug
Two-Hole, Three-Barrel Lug
Figure
No.
1
1
2
Figure
No.
1
1
1
1
2
2
Conductor Size Range
1/0 AWG – 750 kcmil
4/0 AWG – 500 kcmil
#2 AWG – 600 kcmil
500 kcmil – 1000 kcmil
#14 AWG – 1/0 AWG
#6 AWG – 250 kcmil
#6 AWG – 350 kcmil
#2 AWG – 600 kcmil
#6 AWG – 3/0 AWG
Size Range
Conductor
ELECTRICAL SOLUTIONS
Stud Hole
Size
(In.)
3/8
3/8
1/4
Stud
Size
Hole
(In.)
3/8
1/2
1/2
1/2
1/2
1/2
Stud Hole
Spacing
Stud Hole
Spacing
(In.)
1.38
1.38
0.69
• Inspection window to visually assure full conductor insertion
• Plated steel or aluminum set screw provides high strength, durable
• UL Listed and CSA Certified for use up to 600 V and UL
• LAM3LB connector is provided with dual set screws to allow
• For use up to 600 V and temperature rated 90°C
• Available with NEMA hole sizes and spacing
W
T
(In.)
1.00
1.75
1.75
1.75
1.75
1.75
T
electrical contact between conductor and connector
temperature rated 90°C
premium clamping of conductor to connector for heavy
duty applications
W
SPACING
HOLE
P
Figure 1
SPACING
Figure 1
L
HOLE
P
Hex Key
Hex Key
Size
(In.)
L
3/8
3/8
1/2
Size
5/16
5/16
(In.)
1/4
3/8
1/2
**
H2
H1
H
4.91
4.91
2.91
L
2.91
4.25
4.00
4.50
5.50
6.19
L
1.50
1.50
1.44
W
2.00
2.81
2.82
3.50
4.32
5.27
Figure Dimensions
W
Figure Dimensions
W
T
T
3.00
3.00
2.38
SPACING
H1
W
HOLE
P
SPACING
Figure 2
(In.)
0.88
1.19
1.19
1.38
1.50
1.88
(In.)
HOLE
Figure 2
L
H
P
Prime items appear in BOLD.
1.88
1.88
1.77
H2
L
H2
0.25
0.31
0.31
0.31
0.38
0.56
T
0.75
0.75
0.63
H1
T
H
2.16
3.25
3.00
3.25
3.25
3.44
2.34
2.34
1.69
P
P
Pkg.
Pkg.
Std.
Std.
Qty.
Qty.
1
1
1
6
3
1
1
1