EM357-MOD-LR-ANT-T Silicon Labs, EM357-MOD-LR-ANT-T Datasheet - Page 32

no-image

EM357-MOD-LR-ANT-T

Manufacturer Part Number
EM357-MOD-LR-ANT-T
Description
Zigbee / 802.15.4 Modules EM357 Module, w/ PA /LNA, incl. antenna
Manufacturer
Silicon Labs
Datasheet

Specifications of EM357-MOD-LR-ANT-T

Rohs
yes
Frequency Band
2.4 GHz
Data Rate
500 Kbps
Sensitivity
- 100 dBm
Supply Current Transmitting
31 mA
Supply Current Receiving
26 mA
Maximum Operating Temperature
+ 85 C
Dimensions
7.12 mm x 7.12 mm x 1 mm
EM35x Development Kit User Guide
6
6.1
The InSight Adapter (ISA3) provides an Ethernet connection to EM35x devices. You can use the InSight Adapter to
perform the following tasks:
6.2
All the features of the InSight Adapter are available via the Ethernet connection. The ISA3 can also be
connected to a PC via USB to change the Ethernet settings.
When connected via USB, the InSight Adapter will also be powered via USB. It should be connected to a powered
USB hub, or port on your PC that is capable of supplying full power to connected devices.
When connected via Ethernet, the InSight Adapter may be powered in one of two ways:
The ISA3 will also supply power to the connected EM35x device when the power switch is in the INT (Internal)
position. If the connected EM35x device has its own power supply, ensure the power switch is kept in the EXT
(External) position.
You can connect via Ethernet to the ports listed in Table 6-1 using either InSight Desktop or a terminal
application (for example, Microsoft Telnet Client, HyperTerminal, or PuTTY).
Port
4900
4901
4902 or 23
6.3
By default, InSight Adapters are configured to get an IP address via DHCP. They are assigned hostnames of EM-
ISA3-00, EM-ISA3-01, etc. You can use InSight Desktop to discover the ISA3s on the network and see their IP
addresses.
Program and debug using Serial Wire or JTAG.
Monitor packets sent and received by the radio.
Send and receive serial port data.
Send and receive debugging data.
Turn power on and off.
Control reset, bootloader and GPIO signals.
Using the InSight Adapter
Overview
Connectivity and Power
Using an Ethernet switch that supplies Power Over Ethernet (PoE).
Using a USB power supply.
Ethernet Settings
Use
Virtual serial port on EM35x via InSight Port cable.
Physical serial port on EM35x via Data Emulation Interface cable.
Admin interface.
Table 6-1. InSight Adapter Ports
120-4030-000E
6-1

Related parts for EM357-MOD-LR-ANT-T