EM357-MOD-LR-ANT-T Silicon Labs, EM357-MOD-LR-ANT-T Datasheet - Page 14

no-image

EM357-MOD-LR-ANT-T

Manufacturer Part Number
EM357-MOD-LR-ANT-T
Description
Zigbee / 802.15.4 Modules EM357 Module, w/ PA /LNA, incl. antenna
Manufacturer
Silicon Labs
Datasheet

Specifications of EM357-MOD-LR-ANT-T

Rohs
yes
Frequency Band
2.4 GHz
Data Rate
500 Kbps
Sensitivity
- 100 dBm
Supply Current Transmitting
31 mA
Supply Current Receiving
26 mA
Maximum Operating Temperature
+ 85 C
Dimensions
7.12 mm x 7.12 mm x 1 mm
EM35x Development Kit User Guide
For detailed information about the EM35x Module supplied with your kit, see document 120-2011-000, the
EM35x Module Technical Specification.
Once you move away from the EM35x Module and toward application-specific hardware, refer to the extensive
Ember reference design library at www.silabs.com/zigbee-support. Each reference design provides a schematic,
Bill of Materials (BOM), characterization data, and layout files. They are designed and delivered in a manner
that reduces both time to market and hardware implementation risk. For assistance in locating the best design
for your needs, contact support at www.silabs.com/zigbee-support.
3.2.3 InSight Adapter (ISA3)
InSight Adapter (ISA3) provides an efficient and configurable Debug Interface to the Development Kit Breakout
Board for processing emulation and debug commands. It also provides an interface to InSight Desktop for
monitoring and managing network data.
The ISA3 has the following components:
3.3
Table 3-1 lists all of the components and the acceptable combinations of power sources that yield normal
operation. Potential power sources include the following:
Debug Port interface to the Breakout Board’s Extended Debug Interface Connector
InSight Port interface to the radio communication module, providing programming and debugging
services
TCP/IP 10/100 Ethernet interface with Power-over-Ethernet functionality
USB Interface
Acceptable Power Sources for Normal Operation
Power-Over-Ethernet (PoE) Switch
AAA battery pack (3VDC)
USB cable
Power over Insight Port on ISA (the target power select switch on the front panel must be set to Int
(Internal)).
From RCM dedicated power
External DC adapter (not supplied with the Development Kit)
Connected to PC
Connected to USB Power Supply with Adapters
120-4030-000E
3-4

Related parts for EM357-MOD-LR-ANT-T