In a master SPI with the mode fault enable bit (MODFEN) set, the mode fault flag (MODF) is set if SS
goes low. A mode fault in a master SPI causes the following events to occur:
When configured as a slave (SPMSTR = 0), the MODF flag is set if SS goes high during a transmission.
When CPHA = 0, a transmission begins when SS goes low and ends once the incoming SPSCK returns
to its idle level after the shift of the eighth data bit. When CPHA = 1, the transmission begins when the
SPSCK leaves its idle level and SS is already low. The transmission continues until the SPSCK returns
to its IDLE level after the shift of the last data bit. (See
In a slave SPI (MSTR = 0), the MODF bit generates an SPI receiver/error CPU interrupt request if the
ERRIE bit is set. The MODF bit does not clear the SPE bit or reset the SPI in any way. Software can abort
the SPI transmission by toggling the SPE bit of the slave.
To clear the MODF flag, read the SPSCR and then write to the SPCR register. This entire clearing
procedure must occur with no MODF condition existing or else the flag will not be cleared.
Freescale Semiconductor
If ERRIE = 1, the SPI generates an SPI receiver/error CPU interrupt request.
The SPE bit is cleared.
The SPTE bit is set.
The SPI state counter is cleared.
The data direction register of the shared I/O port regains control of port drivers.
To prevent bus contention with another master SPI after a mode fault error,
clear all data direction register (DDR) bits associated with the SPI shared
port pins.
Setting the MODF flag (SPSCR) does not clear the SPMSTR bit. Reading
SPMSTR when MODF = 1 will indicate a MODE fault error occurred in
either master mode or slave mode.
When CPHA = 0, a MODF occurs if a slave is selected (SS is low) and later
deselected (SS is high) even if no SPSCK is sent to that slave. This
happens because SS at 0 indicates the start of the transmission (MISO
driven out with the value of MSB) for CPHA = 0. When CPHA = 1, a slave
can be selected and then later deselected with no transmission occurring.
Therefore, MODF does not occur since a transmission was never begun.
A high voltage on the SS pin of a slave SPI puts the MISO pin in a high
impedance state. Also, the slave SPI ignores all incoming SPSCK clocks,
even if a transmission has begun.
MC68HC908AZ60A • MC68HC908AS60A • MC68HC908AS60E Data Sheet, Rev. 6