emc2104 Standard Microsystems Corp., emc2104 Datasheet - Page 91

no-image

emc2104

Manufacturer Part Number
emc2104
Description
Emc2104 Dual Rpm-based Pwm Fan Controller With Hardware Thermal Shutdown
Manufacturer
Standard Microsystems Corp.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
emc2104-BP-TR
Quantity:
580
Company:
Part Number:
emc2104-BP-TR
Quantity:
580
Dual RPM-Based PWM Fan Controller with Hardware Thermal Shutdown
Datasheet
Appendix B Look Up Table Operation
SMSC EMC2104
B.1
STEP
1
2
3
4
5
6
7
8
Example #1
The EMC2104 uses a look-up table to apply a user-programmable fan control profile based on
measured temperature to each fan driver. In this look-up table, each temperature channel is allowed
to control the fan drive output independently (or jointly) by programming up to eight pairs of
temperature and drive setting entries.
The user programs the look-up table based on the desired operation. If the RPM based Fan Speed
Control Algorithm is to be used (see
temperature setting of interest. Alternately, if the RPM based Fan Speed Control Algorithm is not to be
used, then the user must program a drive setting for each temperature setting of interest.
If the measured temperature on the External Diode channel meets or exceeds any of the temperature
thresholds for any of the channels, the fan output will be automatically set to the desired setting
corresponding to the exceeded temperature. In cases where multiple temperature channel thresholds
are exceeded, the highest fan drive setting will take precedence.
When the measured temperature drops to a point below a lower threshold minus the hysteresis value,
the fan output will be set to the corresponding lower set point.
The following sections show examples of how the Look Up Table is used and configured. Each Look
Up Table Example uses the Fan 1 Look Up Table Registers configured as shown in
This example does not use the RPM based Fan Speed Control Algorithm. Instead, the Look Up Table
is configured to directly set a fan drive setting based on the temperature of four of its measured inputs.
The configuration is set as shown in
Once configured, the Look Up Table is loaded as shown in
temperature configurations using the settings in
Up Table will select.
Setting 3 (5Ch)
Setting 6 (6Bh)
Setting 1 (52h)
Setting 2 (57h)
Setting 4 (61h)
Setting 5 (66h)
Setting 7 (70h)
Setting 8 (75h)
LUT Temp 1
LUT Temp 1
LUT Temp 1
LUT Temp 1
LUT Temp 1
LUT Temp 1
LUT Temp 1
LUT Temp 1
TEMP 1
Setting 3 (5Dh)
Setting 6 (6Ch)
Setting 1 (53h)
Setting 2 (58h)
Setting 4 (62h)
Setting 5 (67h)
Setting 7 (71h)
Setting 8 (76h)
LUT Temp 2
LUT Temp 2
LUT Temp 2
LUT Temp 2
LUT Temp 2
LUT Temp 2
LUT Temp 2
LUT Temp 2
TEMP 2
Table B.1 Look Up Table Format
DATASHEET
Section
Table
91
Setting 3 (5Eh)
Setting 6 (6Dh)
Setting 1 (54h)
Setting 2 (59h)
Setting 4 (63h)
Setting 5 (68h)
Setting 7 (72h)
Setting 8 (77h)
B.2.
LUT Temp 3
LUT Temp 3
LUT Temp 3
LUT Temp 3
LUT Temp 3
LUT Temp 3
LUT Temp 3
LUT Temp 3
6.6), then the user must program an RPM target for each
TEMP 3
Table B.3
and the final fan drive setting that the Look
Setting 2 (5Ah)
Setting 3 (5Fh)
Setting 6 (6Eh)
Setting 1 (55h)
Setting 4 (64h)
Setting 5 (69h)
Setting 7 (73h)
Setting 8 (78h)
LUT Temp 4
LUT Temp 4
LUT Temp 4
LUT Temp 4
LUT Temp 4
LUT Temp 4
LUT Temp 4
LUT Temp 4
Table
TEMP 4
B.3.
Table B.3
Revision 1.74 (05-08-08)
Setting 3 (5Bh)
Setting 6 (6Ah)
Setting 1 (51h)
Setting 2 (56h)
Setting 4 (60h)
Setting 5 (65h)
Setting 7 (6Fh)
Setting 8 (74h)
Table
LUT DRIVE
LUT Drive
LUT Drive
LUT Drive
LUT Drive
LUT Drive
LUT Drive
LUT Drive
LUT Drive
shows three
B.1.

Related parts for emc2104