Functions of the Electrical Angle Timer and Waveform Arithmetic Circuit Registers
Electrical angle
Set voltage amplitude
Capture electrical angle
Set sine wave data
Start calculation by software
Calculation flag
Enable/disable calculation
start synchronized with elec-
trical angle
Electrical angle interrupt
Electrical angle count up/
down
Select V-, W-phase
Select clock
Switch between 2-phase and
3-phase modulations
Auto transfer calculation re-
sults to CPM registers
Enable/disable waveform cal-
culation function
Electrical angle timer
Correct electrical angle period
Electrical angle period
Forcefully start calculation. When this bit is written while the waveform arithmetic circuit is
calculating, the calculation is terminated and then newly started.
By reading this bit, the operation status of the waveform arithmetic circuit can be obtained.
Select whether to start calculation when the electrical angle timer finishes counting or when
a value is set in the electrical angle register. When disabled, calculation is only started when
CALCST is set to 1.
Set the electrical angle interrupt signal request timing to either when the electrical angle
timer finishes counting or upon end of calculation.
Set whether the electrical angle timer counts up or down.
Select phase direction of V-phase and W-phase in relation to U-phase.
Select the clock for the electrical angle timer. This setting can be altered even while the
electrical angle timer is operating.
Select the modulation method with which to perform waveform calculation.
Two-phase modulation DATA = ramdata (ELDEG) × AMP
Note: The ± sign during 3-phase modulation changes depending on the electrical angle.
+ for electrical angles 0 to 179 degrees (191)
− for electrical angles 180 (192) to 360 (383) degrees
Enable/disable transfer of calculation results by the waveform arithmetic circuit. When the
waveform calculation function is enabled while at the same time transfer is enabled, cal-
culation results are set as U, V, and W-phase duty cycles of the PWM generation circuit
and are reflected in the ports.
Enable/disable the waveform calculation function. Calculations are performed by the wave-
form arithmetic circuit by enabling the waveform calculation function. When the waveform
calculation function is enabled, the calculated results can be read from the U, V, and W-
phase compare registers (CMPU, V, W) of the PWM generation circuit.
Enable/disable the electrical angle timer. When enabled, the electrical angle timer starts
counting; when disabled, the electrical angle timer stops counting and is cleared to 0.
Correct the period by adding 1 to electrical angle counts 16 for “n” times. The timer counts
the electrical angle period set value “m”’for (16 − n) times and counts (m + 1) for “n” times
Set the electrical angle period.
Read the electrical angle. This register can also be set to initialize or correct the angle while
counting. Any value greater than 17FH cannot be set.
Set the voltage amplitude. The waveform arithmetic circuit multiplies the data set here by
the sine wave data read out from the sine wave RAM. The amplitude has its upper limit
determined by the set value of the MDPRD register when performing this multiplication.
Capture the value from the electrical angle timer when the position is detected.
To initialize the entire RAM data of the sine wave table, set the addresses at which to set,
sequentially from 000H to 17FH, in the ELDEG register, and write waveform data to the
WFMDR register each time. Make sure the waveform arithmetic circuit is disabled when
writing this data.